- CPTG
-
GOSSEN
-
瑞士富巴(HUBA)
- 美国HTM接近开关、电感...
-
美国美亚过程控制公司Me...
-
952 系列法兰型孔板流...
-
951 偏心孔板流量计(...
-
72H系列高压湿塔Acc...
-
70H系列高压湿塔Acc...
-
43H系列插入式带一体式...
-
40H系列插入式带一体式...
-
37L系列高压湿塔Acc...
-
33T系列低压型Accu...
-
25D系列法兰安装型Ac...
-
24D 系列法兰安装型A...
-
23L系列高压型,插入式...
-
22L系列高压型,插入式...
-
21T系列低压型,插入式...
-
20T系列低压型,插入式...
-
11A系列内嵌型Accu...
-
10A系列内嵌型Accu...
-
Meriam孔板流量解决...
-
ACCUTUBE流量解决...
-
MP-100KT 校准泵
-
1020 差压单元
-
952 系列法兰型孔板流...
- 物液位测量与控制
- 流量测量产品
- 过程称重与控制
-
电量测量与控制
-
COMBINE M201...
-
COMBINELINE系...
-
COMBINE 3580...
-
COMBINE 3500...
-
MZC-203回路阻抗测...
-
MRP-120系列RCD...
-
MMR-620欧姆表
-
MRU-200接地电阻和...
-
CMP2钳形表
-
TKF-13相序和电机旋...
-
TKF-12C相序测试仪
-
MIC系列绝缘电阻测试仪
-
MIE 5000电气安装...
-
MPI 5200多功能电...
-
MPI 5250多功能电...
-
COMBINE 1414...
-
COMBINE 1007...
-
COMBINE 1005...
-
COMBINE 1312...
-
COMBINE 31XX...
-
COMBINE M201...
-
液体分析与控制
-
浊度测量控制仪
-
PH和电余氯测量控制仪
- 电导率测量控制仪
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
浊度测量控制仪
-
气体分析与测量
- 过程校准器
- 室内空气质量分析仪
- 暖通燃烧分析仪
- 手持式工业排放分析仪
- 美国新星气体分析系统
- 德国汉斯(Hans He...
- 美国塞弗(safetys...
-
日本RIKEN 系列气体...
- RM-570/580 系...
- GP-641 系列控制器
- GP-146 指示报警单...
- RM-590 系列控制器
- GD-K71D型智能型半...
- GD-F77D-NT 氧...
- GD-F77D氧气(O2...
- GD-V77D-NT 可...
- GD-V77D可燃气体探...
- GD-S77DG-NT ...
- GD-S77DG有毒气体...
- GD-K77DG-NT有...
- GD-K77DG有毒气体...
- GD-K71D-NT 毒...
- GD-K71D毒性气体探...
- GD-K7DII 吸入式...
- GD-D5C 吸入式可燃...
- GD-D8 吸入式可燃气...
- RI-215系列 红外线...
- GD-F44 扩散式氧气...
-
丙烯酸丁酯探测器
-
异丙醇气体探测器
-
磷化氢气体探测器
-
氢氰酸气体探测器
-
硫化氢气体探测器
-
正己烷气体探测器
-
硅甲烷气体探测器
-
氯化氢气体探测器
-
环氧乙烷探测器
-
乙酸乙酯探测器
-
六氟化硫探测器
-
四氟化碳探测器
- 压力测量与控制
-
温度测量与控制
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
阀门及气电转换产品
-
TOKO东控阀门(原装进...
- V-6850系列陶瓷碟型...
- V-6500C系列高压小...
- V-6420系列浮筒式单...
- T-8710系列钽材波纹...
- T-8660系列Y型先导...
- T-8320系列小型三通...
- T-8050系列小型全塑...
- T-5705系列高压波纹...
- T-5675系列衬胶可分...
- T-8960系列直通波纹...
- T-8950系列角形波纹...
- T-8940系列隔膜角型...
- T-8930系列一体三通...
- T-8910系列分体角型...
- T-8900系列分体直通...
- R-2000系列衬胶滚筒...
- V-5514系列金属密封...
- V-5513系列PTFE...
- V-5512系列橡胶密封...
- V-5510系列双偏心蝶...
- AKO系列管夹阀
-
美国COMBINE执行机...
- YT-405型保位阀
- YT-300型气动放大器
- AS3000-02型速度...
- SR/AW30型过滤减压...
- ITS300型角行程防爆...
- ITS100型角行程限位...
- 1Lx7001型直行程防...
- WLGCA2型直行程限位...
- M15G-8型两位五通电...
- M00U-8型两位三通电...
- 3760型小型内藏式阀门...
- YVP-110型数字式阀...
- IP-8001型HART...
- TP-601型气/气阀门...
- TP-351型电/气阀门...
- CMC-103电动式执行...
- CMS-020/040电...
- PSN系列高性能电子式伺...
- MSP系列小型电子式执行...
- C-25系列汽缸式执行机...
- 美国COMBINE电气转...
-
德国西门子SIEMENS...
- 771系列电气转换器Cu...
- 77 系列电气转换器Cu...
- 73N-B1内置式阀门定...
- 73N-B内置式阀门定位...
- 73N-FR内置式阀门定...
- 73N24F内置式阀门定...
- 73N12F内置式阀门定...
- 74-SN1阀门定位器 ...
- 74-SG1阀门定位器 ...
- 760P6阀门定位器 V...
- 760P5阀门定位器 V...
- 760P4阀门定位器 V...
- 760P2阀门定位器 V...
- 760P1阀门定位器 V...
- 760E1阀门定位器 V...
- 2306系列仪表空气过滤...
- 91-HF系列过滤减压阀...
- 661带偏压 的放大继电...
- 66 放大和减小继电器A...
- 63SDL常数差流量控制...
- 芬兰Larox 阀门(管...
-
TOKO东控阀门(原装进...
- 便携式检测仪器
- 系统与集成
- 美国诺南RONAN公司测...
- 美国ELECTROSWI...
- 美国PRECISION系...
- 瑞士Rotronic温湿...
产品资料
简单介绍:
Multi-stage, low-droop precision regulators maintain constant
output over wide changes in flow and supply pressure
Epoxy powder coat paint delivers improved corrosion
resistance
Wide selection of regu
详情介绍:
Features & Benefits:
Multi-stage, low-droop precision regulators maintain constant output over wide changes in flow and supply pressure
Epoxy powder coat paint delivers improved corrosion resistance
Wide selection of regulated pressures [1" to 450 psi] affords application versatility
Patented Nullmatic pressure regulation system providesreliable maintenance-free operation
Description
The Models 40, 41, and 42 Precision Pressure Regulators control air pressures in applications where precise and
dependable regulation is required, such as pneumatic instrument circuits, test stands, production checking fixtures,
and industrial air gages. As such, they are suitable for dead-end service, and flows up to a maximum of 110 scfm.
A unique, two-stage piloted design provides outstanding accuracy. Rugged construction—with no links, levers,
pivots, or other friction-producing members—ensures reliable, maintenance-free operation. These features allow
a regulator to maintain constant output pressure, regardless of even the widest changes in flow or supply pressures. In
fact, a regulator using a Model 40, 41, or 42 is practically a self-contained pressure controller operating its supply-
plunger valve via a built-in, high-gain pneumatic amplifier.A fine-turn, precision screw is used to manually load the
range spring, which sets the regulated pressure. When the adjusting knob is turned clockwise, the increased spring
force is exerted on the top diaphragm assembly,decreasing the nozzle clearance and increasing the pilot pressure. Because the source for pilot pressure is supply air flowing to the pilot pressure chamber through the restriction
screw, the increased pilot pressure forces the exhaust diaphragm assembly downward. This action closes the exhaust port, and contacts and moves the valve plunger,which opens the supply port. This increases the regulated output, which also feeds back to the top diaphragm assembly. The regulator locks-up or throttles at the new output value when the feedback force of the top diaphragm assembly equals the range spring force.A safety release valve is incorporated in the top diaphragm assembly of several models. It operates if the regulated pressure increases 3 tnÚ psig more than the set pressure and exhausts air through the atmospheric vent in the top housing. Overpressure causes the diaphragm to move upward, which opens the safety release valve.
Specifications
Resolution Adjustment
Better than 0.03º of regulated output
Supply Pressure
Maximum & recommended pressures are listed on page 220
Minimum: 5 psig above regulated output
Supply Pressure Effect
Nominal ratio of change in regulated pressure for a change
in supply
1:150 for Model 40 and 42
1:100 for Model 41
Ambient Temperature Limits
-40 to 180ºF (-40 to 80ºC)
Ambient Temperature Effect
Approximately 1% of set pressure with standard range
spring; and approximately 0.1% with Isothermal spring for
50°F (27ºC) temperature change
Knob Adjustment
Model 40 & 42: Nominal 10% of full range for one complete turn
Model 41: Nominal 15% of full range for one complete turn
Droop Effect
See Graph 1
Maximum Air Flow
See Graph 2
Air Consumption
See Graph 3
Drift Effect
See Graph 4
Exhaust-Flow Rate (at 25-psig setting)
Pressure rise of 0.25 psig will result from flow of:
Model 40: 1.5 scfm
Model 41: 2.4 scfm
Model 42: 1.7 scfm
Maximum Flow Capacity
See Graph on page 219
Standard Mounting
In-line pipe or flush panel up to 1/4" thick (bushing for 3/4"
thick panel is optional)
Connections: (supply and outlet)
Model 40: 1/4" NPT
Model 41: 1/8" NPT
Model 42: 1/2" NPT
Materials of Construction
(and materials in contact with
regulated media)
Brass, stainless steel, Neoprene, aluminum, and zinc
Accessories
P/N 2932-19 - Mounting Bracket
for surface mounting
(Model 40 and Model 42)
P/N 10963-73 - Mounting Bracket
for surface mounting
(Model 41)
P/N 3603-22 - Locknut
Options
Air Loading
Provision for supplementary air loading (100 psig max) in
addition to spring loading
Model 40, 42: 1/4" NPT
Model 41: 1/8" NPT
Model 40-2: Not available
Add [A] into the model number.
Example: 40A15
Tapped Exhaust
Provision for piping exhaust flow away from the regulator
Model 40, 42: 1/8" NPT
Model 41: Not available
Add [E] into the model number.
Example: 40E15
Isothermal Range Spring
Reduces ambient temperature effect from approximately
1% of set pressure to approximately 0.1% for a 50°F
[27°C] temperature range
Model 40: 15, 30, 50, & 100 psig ranges
Model 41: Not available
Model 42: 30, 50, & 100 psig ranges
Add (M9) to the Moore 40 number.
Add (M26) to the Moore 42 model number.
Example: 40-15M9, 42-30M26
Deletion of Safety Release Valve (SRV)
The SRV increases exhaust flow capacity when the
regulator must exhaust large flows. Deletion of the SRV will
improve drift characteristics (see Graph 4). The SRV is not
available with the Moore 41. It is standard with:
Model 40: 2, 7, 15, 30, 50 & H50 pressure ranges
Model 42: 15, 30, 50, H30, & H50 pressure ranges
To delete the SRV, add an [X] into the model number.
Example: 40X15
Slotted Adjusting Screw
Available for all models. This option provides for screw-
driver adjustment of the regulator and includes a locknut.
Model 40: Add (M3) after the model number
Model 41: Add (M3) after the model number
Model 41: Add (M20) after the model number
Example:
40-15(M3)
Locknut with Longer Adjusting Screw
Available for all models. This option prevents inadvertent
regulator adjustment.
Model 40: Add (M13) after the model number.
(Note: The Model 40-2 is standard with the lock nut.)
Model 41: Add (M5) after the model numberor order
accessory P/N 3603-22.
Model 42: Add (M3) after the model number
Example: 40-15(M3)
Bushings
for mounting on panels up to 3/4" thick
(Standard maximum is 1/4" thick).
Model 40: Add (M41) after the model number
Model 41: Not available
Model 42: Add (M14) after the model number
Example: 40-15(M41)
Multi-stage, low-droop precision regulators maintain constant output over wide changes in flow and supply pressure
Epoxy powder coat paint delivers improved corrosion resistance
Wide selection of regulated pressures [1" to 450 psi] affords application versatility
Patented Nullmatic pressure regulation system providesreliable maintenance-free operation
Description
The Models 40, 41, and 42 Precision Pressure Regulators control air pressures in applications where precise and
dependable regulation is required, such as pneumatic instrument circuits, test stands, production checking fixtures,
and industrial air gages. As such, they are suitable for dead-end service, and flows up to a maximum of 110 scfm.
A unique, two-stage piloted design provides outstanding accuracy. Rugged construction—with no links, levers,
pivots, or other friction-producing members—ensures reliable, maintenance-free operation. These features allow
a regulator to maintain constant output pressure, regardless of even the widest changes in flow or supply pressures. In
fact, a regulator using a Model 40, 41, or 42 is practically a self-contained pressure controller operating its supply-
plunger valve via a built-in, high-gain pneumatic amplifier.A fine-turn, precision screw is used to manually load the
range spring, which sets the regulated pressure. When the adjusting knob is turned clockwise, the increased spring
force is exerted on the top diaphragm assembly,decreasing the nozzle clearance and increasing the pilot pressure. Because the source for pilot pressure is supply air flowing to the pilot pressure chamber through the restriction
screw, the increased pilot pressure forces the exhaust diaphragm assembly downward. This action closes the exhaust port, and contacts and moves the valve plunger,which opens the supply port. This increases the regulated output, which also feeds back to the top diaphragm assembly. The regulator locks-up or throttles at the new output value when the feedback force of the top diaphragm assembly equals the range spring force.A safety release valve is incorporated in the top diaphragm assembly of several models. It operates if the regulated pressure increases 3 tnÚ psig more than the set pressure and exhausts air through the atmospheric vent in the top housing. Overpressure causes the diaphragm to move upward, which opens the safety release valve.
Specifications
Resolution Adjustment
Better than 0.03º of regulated output
Supply Pressure
Maximum & recommended pressures are listed on page 220
Minimum: 5 psig above regulated output
Supply Pressure Effect
Nominal ratio of change in regulated pressure for a change
in supply
1:150 for Model 40 and 42
1:100 for Model 41
Ambient Temperature Limits
-40 to 180ºF (-40 to 80ºC)
Ambient Temperature Effect
Approximately 1% of set pressure with standard range
spring; and approximately 0.1% with Isothermal spring for
50°F (27ºC) temperature change
Knob Adjustment
Model 40 & 42: Nominal 10% of full range for one complete turn
Model 41: Nominal 15% of full range for one complete turn
Droop Effect
See Graph 1
Maximum Air Flow
See Graph 2
Air Consumption
See Graph 3
Drift Effect
See Graph 4
Exhaust-Flow Rate (at 25-psig setting)
Pressure rise of 0.25 psig will result from flow of:
Model 40: 1.5 scfm
Model 41: 2.4 scfm
Model 42: 1.7 scfm
Maximum Flow Capacity
See Graph on page 219
Standard Mounting
In-line pipe or flush panel up to 1/4" thick (bushing for 3/4"
thick panel is optional)
Connections: (supply and outlet)
Model 40: 1/4" NPT
Model 41: 1/8" NPT
Model 42: 1/2" NPT
Materials of Construction
(and materials in contact with
regulated media)
Brass, stainless steel, Neoprene, aluminum, and zinc
Accessories
P/N 2932-19 - Mounting Bracket
for surface mounting
(Model 40 and Model 42)
P/N 10963-73 - Mounting Bracket
for surface mounting
(Model 41)
P/N 3603-22 - Locknut
Options
Air Loading
Provision for supplementary air loading (100 psig max) in
addition to spring loading
Model 40, 42: 1/4" NPT
Model 41: 1/8" NPT
Model 40-2: Not available
Add [A] into the model number.
Example: 40A15
Tapped Exhaust
Provision for piping exhaust flow away from the regulator
Model 40, 42: 1/8" NPT
Model 41: Not available
Add [E] into the model number.
Example: 40E15
Isothermal Range Spring
Reduces ambient temperature effect from approximately
1% of set pressure to approximately 0.1% for a 50°F
[27°C] temperature range
Model 40: 15, 30, 50, & 100 psig ranges
Model 41: Not available
Model 42: 30, 50, & 100 psig ranges
Add (M9) to the Moore 40 number.
Add (M26) to the Moore 42 model number.
Example: 40-15M9, 42-30M26
Deletion of Safety Release Valve (SRV)
The SRV increases exhaust flow capacity when the
regulator must exhaust large flows. Deletion of the SRV will
improve drift characteristics (see Graph 4). The SRV is not
available with the Moore 41. It is standard with:
Model 40: 2, 7, 15, 30, 50 & H50 pressure ranges
Model 42: 15, 30, 50, H30, & H50 pressure ranges
To delete the SRV, add an [X] into the model number.
Example: 40X15
Slotted Adjusting Screw
Available for all models. This option provides for screw-
driver adjustment of the regulator and includes a locknut.
Model 40: Add (M3) after the model number
Model 41: Add (M3) after the model number
Model 41: Add (M20) after the model number
Example:
40-15(M3)
Locknut with Longer Adjusting Screw
Available for all models. This option prevents inadvertent
regulator adjustment.
Model 40: Add (M13) after the model number.
(Note: The Model 40-2 is standard with the lock nut.)
Model 41: Add (M5) after the model numberor order
accessory P/N 3603-22.
Model 42: Add (M3) after the model number
Example: 40-15(M3)
Bushings
for mounting on panels up to 3/4" thick
(Standard maximum is 1/4" thick).
Model 40: Add (M41) after the model number
Model 41: Not available
Model 42: Add (M14) after the model number
Example: 40-15(M41)