- CPTG
-
GOSSEN
-
瑞士富巴(HUBA)
- 美国HTM接近开关、电感...
-
美国美亚过程控制公司Me...
-
952 系列法兰型孔板流...
-
951 偏心孔板流量计(...
-
72H系列高压湿塔Acc...
-
70H系列高压湿塔Acc...
-
43H系列插入式带一体式...
-
40H系列插入式带一体式...
-
37L系列高压湿塔Acc...
-
33T系列低压型Accu...
-
25D系列法兰安装型Ac...
-
24D 系列法兰安装型A...
-
23L系列高压型,插入式...
-
22L系列高压型,插入式...
-
21T系列低压型,插入式...
-
20T系列低压型,插入式...
-
11A系列内嵌型Accu...
-
10A系列内嵌型Accu...
-
Meriam孔板流量解决...
-
ACCUTUBE流量解决...
-
MP-100KT 校准泵
-
1020 差压单元
-
952 系列法兰型孔板流...
- 物液位测量与控制
- 流量测量产品
- 过程称重与控制
-
电量测量与控制
-
COMBINE M201...
-
COMBINELINE系...
-
COMBINE 3580...
-
COMBINE 3500...
-
MZC-203回路阻抗测...
-
MRP-120系列RCD...
-
MMR-620欧姆表
-
MRU-200接地电阻和...
-
CMP2钳形表
-
TKF-13相序和电机旋...
-
TKF-12C相序测试仪
-
MIC系列绝缘电阻测试仪
-
MIE 5000电气安装...
-
MPI 5200多功能电...
-
MPI 5250多功能电...
-
COMBINE 1414...
-
COMBINE 1007...
-
COMBINE 1005...
-
COMBINE 1312...
-
COMBINE 31XX...
-
COMBINE M201...
-
液体分析与控制
-
浊度测量控制仪
-
PH和电余氯测量控制仪
- 电导率测量控制仪
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
浊度测量控制仪
-
气体分析与测量
- 过程校准器
- 室内空气质量分析仪
- 暖通燃烧分析仪
- 手持式工业排放分析仪
- 美国新星气体分析系统
- 德国汉斯(Hans He...
- 美国塞弗(safetys...
-
日本RIKEN 系列气体...
- RM-570/580 系...
- GP-641 系列控制器
- GP-146 指示报警单...
- RM-590 系列控制器
- GD-K71D型智能型半...
- GD-F77D-NT 氧...
- GD-F77D氧气(O2...
- GD-V77D-NT 可...
- GD-V77D可燃气体探...
- GD-S77DG-NT ...
- GD-S77DG有毒气体...
- GD-K77DG-NT有...
- GD-K77DG有毒气体...
- GD-K71D-NT 毒...
- GD-K71D毒性气体探...
- GD-K7DII 吸入式...
- GD-D5C 吸入式可燃...
- GD-D8 吸入式可燃气...
- RI-215系列 红外线...
- GD-F44 扩散式氧气...
-
丙烯酸丁酯探测器
-
异丙醇气体探测器
-
磷化氢气体探测器
-
氢氰酸气体探测器
-
硫化氢气体探测器
-
正己烷气体探测器
-
硅甲烷气体探测器
-
氯化氢气体探测器
-
环氧乙烷探测器
-
乙酸乙酯探测器
-
六氟化硫探测器
-
四氟化碳探测器
- 压力测量与控制
-
温度测量与控制
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
阀门及气电转换产品
-
TOKO东控阀门(原装进...
- V-6850系列陶瓷碟型...
- V-6500C系列高压小...
- V-6420系列浮筒式单...
- T-8710系列钽材波纹...
- T-8660系列Y型先导...
- T-8320系列小型三通...
- T-8050系列小型全塑...
- T-5705系列高压波纹...
- T-5675系列衬胶可分...
- T-8960系列直通波纹...
- T-8950系列角形波纹...
- T-8940系列隔膜角型...
- T-8930系列一体三通...
- T-8910系列分体角型...
- T-8900系列分体直通...
- R-2000系列衬胶滚筒...
- V-5514系列金属密封...
- V-5513系列PTFE...
- V-5512系列橡胶密封...
- V-5510系列双偏心蝶...
- AKO系列管夹阀
-
美国COMBINE执行机...
- YT-405型保位阀
- YT-300型气动放大器
- AS3000-02型速度...
- SR/AW30型过滤减压...
- ITS300型角行程防爆...
- ITS100型角行程限位...
- 1Lx7001型直行程防...
- WLGCA2型直行程限位...
- M15G-8型两位五通电...
- M00U-8型两位三通电...
- 3760型小型内藏式阀门...
- YVP-110型数字式阀...
- IP-8001型HART...
- TP-601型气/气阀门...
- TP-351型电/气阀门...
- CMC-103电动式执行...
- CMS-020/040电...
- PSN系列高性能电子式伺...
- MSP系列小型电子式执行...
- C-25系列汽缸式执行机...
- 美国COMBINE电气转...
-
德国西门子SIEMENS...
- 771系列电气转换器Cu...
- 77 系列电气转换器Cu...
- 73N-B1内置式阀门定...
- 73N-B内置式阀门定位...
- 73N-FR内置式阀门定...
- 73N24F内置式阀门定...
- 73N12F内置式阀门定...
- 74-SN1阀门定位器 ...
- 74-SG1阀门定位器 ...
- 760P6阀门定位器 V...
- 760P5阀门定位器 V...
- 760P4阀门定位器 V...
- 760P2阀门定位器 V...
- 760P1阀门定位器 V...
- 760E1阀门定位器 V...
- 2306系列仪表空气过滤...
- 91-HF系列过滤减压阀...
- 661带偏压 的放大继电...
- 66 放大和减小继电器A...
- 63SDL常数差流量控制...
- 芬兰Larox 阀门(管...
-
TOKO东控阀门(原装进...
- 便携式检测仪器
- 系统与集成
- 美国诺南RONAN公司测...
- 美国ELECTROSWI...
- 美国PRECISION系...
- 瑞士Rotronic温湿...
产品资料
简单介绍:
The PD6000 digital panel meter is a full-featured, high end, digital process meter that represents the continuum of 34 years of development by Precision Digital Corporation. The most noticeable featur
详情介绍:
Feature Rich and Flexible
The ProVu® digital panel meter boasts specifications and functionality that clearly make it one of the most advanced process meters available. Its dual-line 6-digit display (999,999), advanced math functions, function keys, Modbus RTU serial communications, and optional expansion modules are only a few of the features found on the ProVu PD6000.FRONT PANEL DISPLAY
Precise, Accurate, and More Informative
ProVu's large 0.6" upper display provides a highly accurate and precise 6-digit view of the process measurement. Its 24-bit A/D is accurate to ± 0.03% of calibrated span ±1 count.Configurable
The upper display can be programmed to indicate PV, maximum (peak), minimum (valley), alternating maximum/minimum, one of eight alarm set points, or Modbus input. The lower display can also be configured to display engineering units, set points, user defined legends, or simply turned off.Optional SunBright Display Models
ProVu's SunBright display models have an extraordinarily bright LED display. They are perfect for applications where the meter is in direct sunlight or in applications where visibility may be impaired by smoke, fog, dust, or distance. There are 8 user selectable intensity levels to choose from on all ProVu models. This option is available on all ProVu models.
Function KeysThere are three function keys available to the user. These keys can be programmed to trigger certain events (i.e. acknowledge alarms, reset max and/or min, disable/enable output relays, or hold current relay states), provide direct menu access points, and more.Learn more about using the ProVu's Function Keys by watching a video click here to watch. |
|
RuggedA unique front panel design makes the ProVu digital panel meter nearly impenetrable in typical applications. Here, the ProVu easily survives a direct hit on the display from a heavy 2" solid stainless steel ball dropped from eight feet. |
|
Easy to UseThe user friendly dual-line display makes the ProVu easy to set up& program. No jumpers to set for input selection. All setup & programming is done via the front panel. Three levels of password protection help maintain the reliability of the programming. Dual-Scale Display FeatureThe ProVu PD6000 has a rather unique and very flexible dual-scale capability; a second scaled display can represent the measured input in a different form (i.e. gallons & height). This is of particular value in level applications. Please see the examples shown below. Both displays are independently scaled and are based on the 4-20 mA input signal. Beyond level, this function has been used for pressure & force, current & power, feet & meters, GPM & CFM, and more. |
|
![]() Gallons and mA |
![]() Gallons and Height |
![]() Gallons and Percent |
![]() Gallons and Head PSI |
Three Tier Password Protection
The ProVu offers 3 levels of password protection:- Level 1 protection allows the operator use of only the 3 pre-configured function keys on the front panel without a password.
- Level 2 protection allows the operator use of only the function keys and the ability to change set points without a password.
- Level 3 protection restricts the operator from using the function keys and all meter configuration menus without a password.
Advanced Linearization Capability
The ProVu includes a 32-point linearizer. In non-linear level applications (i.e. some pumping or lift stations), it can easily compensate for submerged equipment or plumbing that displace usable volume. A second independent 8-point linearizer is available for a second scaled display (PV2) when "Level" function is enabled. Precision Digital's free MeterView Pro PC-based software greatly simplifies the construction of the linearization tables. The software can save this data to the meter and/or PC.Simplified & Dynamic Menu System
The ProVu minimizes the menu selections by auto-detecting the installed options to determine what menu navigation is required. For example, extra menu items for the relay expansion module, I/O expansion, etc. are not present unless those options have been installed. This is an example of keeping the product simply sophisticated.Max/Min Display
Max/Min (or Peak/Valley) is standard on the ProVu PD6000. Either display can be configured to show either maximum or minimum excursion since last reset. The displays can also be configured to toggle between Max and Min values. Both values can be simply reset from the front panel.Environmentally Protected
The ProVu has standard UV protection, a NEMA 4X front panel, extremely durable face plate, performs in wide ambient operating temperatures, and is CE Certified (high noise and RF immunity).DIGITAL COMMUNICATIONS
Modbus® RTU Serial Communications
After the purchase of a serial communication adapter for the ProVu meter, any Modbus-ready Master device can communicate with the meter using the ever-popular Modbus communications protocol included in every ProVu. This greatly increases the flexibility of the meter. Modbus provides much more capability than read PV and write set points. Below are some examples of other things that can be done with ProVu's Modbus communications.
- Send a 6-character message to the lower display upon an event
- Convert a digital value to a 4-20 mA signal
- Remote user control (i.e. change set points, acknowledge alarms)
- Input a Modbus digital PV (in place of analog input)
- Remote override of any, or all, relays and analog outputs
Meter Copy
The Copy feature is used to copy (or clone) all the settings from one ProVu to other ProVu meters in about 20 seconds! The Copy function is a standard feature on all meters. It does not require a communications adapter, only an optional cable assembly, P/N PDA1200. See the ordering information for complete details.
Click here to see the
ProVu videos
ProVu VIDEOS
Watch a quick demonstration on how the ProVu works and also how the function keys can simplify functionality. These and other videos are available click here.FIELD EXPANSION MODULES
Add functionality to the ProVu in the field with easy-to-install external expansion modules. Add RS-232 or RS-422/485 communications, I/O modules (up to 2), or 4-relay expansion module. The menu items for these modules do not appear until the module is connected, simplifying the basic menu. Relay and digital I/O modules are shown below with optional DIN rail mounting kit, P/N PDA1002.
PDA1044 I/O Expansion Module
Four digital inputs and four digital outputs are available per expansion module. The ProVu meter will accept two of these modules. External digital inputs can function similarly to the front panel function keys. They can be configured to trigger certain events (i.e. acknowledge/reset alarms, reset max and/or min values, disable/enable all output relays, and hold current relay states), provide direct menu access point, or mimic front panel keys. The I/O module can be used to configure the ProVu remotely, in essence giving the user control of the four front panel push buttons. This feature is particularly useful if the meter is mounted inside an explosion-proof enclosure.Digital outputs can be used to remotely monitor ProVu's alarm relay output states, or the states of a variety of actions and functions executed by the meter.
PDA1004 Relay Expansion ModuleAn external module containing four 3 A Form A (SPST) relays can be added to the ProVu at anytime.Removable screw terminal blocks accept 12 to 22 AWG wire. |
![]() |
![]() |
PDA1232 & PDA1485 Communication ModulesSerial communications on the ProVu can be added anytime with external PDA1232 (RS-232) or PDA1485 (RS-422/485) communication adapters. |
METERVIEW® PRO SOFTWARE
Click here to see the
ProVu videos
Monitor and Datalog |
|
![]() Setup |
|
![]() Programming |
|
Relays |
|
OUTPUTS
Relay Outputs
| The ProVu has up to four 3 A Form C relays (SPDT) with multiple power loss fail-safe options. Relays can be configured for proper protective action upon input loop break. Relay ON and OFF delay times are user adjustable. Up to eight front panel indicators show alarm and/or relay state. All relays can be configured for 0-100% deadband. | |
Relay Operation/Configuration
There are powerful relay functions that can be configured in the ProVu meter, including:- Automatic reset only (non-latching)
- Automatic + manual reset at any time (non-latching)
- Latching (manual reset only)
- Latching with Clear (manual reset only after alarm condition has cleared)
- Pump alternation control (automatic reset only)
- Sampling (activated for a user-specified time)
- User selectable fail-safe operation
- Relay action for loss (break) of 4-20 mA input signal
- Time delay (on and off), independent for each relay
- Manual control mode
- Interlock relay mode
Analog Output
The isolated analog retransmission signal can be configured to represent the process variable (PV), maximum (peak) value, minimum (valley) value, the value for any of the eight relay set points, or Modbus input. While the output is nominally 4-20 mA, the signal will accurately accommodate under- and over-ranges from 1 to 23 mA.
Auto/Manual Control
Take control of any output with this feature. All relays can be forced ON or OFF, and the 4-20 mA output signal can be set to any value within its range. When the relays and 4-20 mA output are controlled manually, an LED labeled "M" is turned on and the associated Alarm LEDs (1-8) flash every 10 seconds indicating that the meter is in manual control mode.Isolated Transmitter Power Supplies
A powerful 24 V @ 200 mA power supply is a standard feature on the ProVu meter. It can be configured for 5, 10, or 24 V (default) by means of a simple internal jumper (see manual). An additional power supply (24 V @ 40 mA) is standard with the 4-20 mA output option.Sampling Function (PV Triggered Timed Relay)
The sampling function allows the operator to set a set point for a "sampling" relay. When the PV reaches that set point, it will close that relay's contacts for a preset period of time (0.1 to 5999.9 seconds). An example of its use may be for beer/ale fermentation. When the batch reaches a certain pH, the relay contacts would close and by some means (light, horn, etc.) alert someone to take a sample, or provide the trigger to automatically take a sample of the batch. The utility of this function can, of course, be expanded beyond sampling and be used whenever a timed relay output closure is required when the PV reaches a certain set point.
Interlock Relay(s)
This function allows a process to use one or more very low voltage input signals or simple switch contacts to control the state of one or more internal "interlock" relays. A violation (i.e. loss of input, open switch, or open circuit) forces one or more N/O interlock relay contacts to open. One input can be used in series with a number of interlock switches, or up to eight inputs can be required to force-on one (or more) internal interlock relays. Please see Application Note AN-1008 for more information.Note: Requires PDA1044 Digital I/O module.
MATH FUNCTIONS
Non-linear input signals (i.e. weirs & flumes, differential pressure, etc.) can be linearized with the ProVu's simple to use built-in math functions, such as: square-root extractor, exponential linearizer, horizontal round tank linearizer, or the ProVu's powerful general purpose 32-point linearizer.| Weir Flow Calculated Using Exponential Math Function |
![]() |
| Round Horizontal Tank Math Function |
![]() |
Click here to see the
Multi-pump alternation video
Multi-Pump Alternation
For pump control applications where 2 or more similar pumps are used to control the level of a tank or a well, it is desirable to have the pumps operate alternately; this prevents excessive wear and overheating of one pump over the lack of use of the others. The ProVu can accommodate up to 8 pumps. In the example below, a pair of relays have been set up to alternate every time an on/off pump cycle is completed. Another pair of relays is used for low and high alarms.
Relay #4 turns the main pump on at 6000 gallons and turns it off at 1000 gallons.
With the Pump Alternation feature activated, the next time the level reaches 6000 gallons, relay #3 transfers and starts the backup pump.
If the backup pump is not able to keep up, and the level reaches 7000 gallons, relay #4 transfers and starts the main pump as well.
Relay #2 trips the High Level Alarm at 7500 gallons and resets at 6900 gallons.
Relay #1 trips the Low Level Alarm at 495 gallons and resets at 750 gallons.
NEMA 4 & 4X FIELD ENCLOSURESPlastic, stainless steel, and painted steel NEMA 4 enclosures for up to 10 ProVu meters. |
![]() Enter the Enclosure Selection Utility |
CONNECTIONS
SPECIFICATIONS
Except where noted all specifications apply to operation at +25°CGeneral
Display: Upper display: 0.60" (15 mm) high. Lower display: 0.46" (12 mm) high. Both displays are 6 digits (-99999 to 999999), red LEDs with leading zero blanking.Display Intensity: Eight intensity levels
Display Update Rate: 5/second (200 ms)
Overrange: Display flashes 999999
Underrange: Display flashes -99999
Display Assignment: The upper & lower displays may be assigned to PV1, PV2, PCT (percent), max/min, alternate max & min, set points, units (lower display only), and Modbus input.
Front Panel: NEMA 4X, IP65
Programming Methods: Four front panel buttons, digital inputs, PC and MeterView Pro software, Modbus registers, or cloning using Copy function.
Noise filter: Programmable from 2 to 199 (0 will disable filter)
Filter Bypass: Programmable from 0.1 to 99.9% of calibrated span
Recalibration: Calibrated at the factory. Recalibration is recommended at least every 12 months
Max/Min Display: Max (peak) / min (valley) readings reached by the process are stored until reset by the user or until power to the meter is cycled
Password: Three programmable passwords restrict modification of programmed settings. Pass 1: Allows use of function keys and digital inputs. Pass 2: Allows use of function keys, digital inputs and editing set/reset points. Pass 3: Restricts all programming, function keys, and digital inputs.
Non-Volatile Memory: All programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost
Power Options: 85-265 VAC 50/60 Hz, 90-265 VDC 20 W max or jumper selectable 12/24 VDC ±10%, 15W max.
Fuse: Required external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse
Isolated Transmitter Power Supply: Terminals P+ ∓ P-: 24 VDC ±5% @ 200 mA max (standard), (12/24 VDC powered models rated @ 100 mA max). 5 or 10 VDC @ 50 mA max, selectable with internal jumper J4.
Normal Mode Rejection: Greater than 60 dB at 50/60 Hz
Isolation: 4 kV input/output-to-power line. 500 V input-to-output or output-to-P+ supply
Overvoltage Category: Installation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.
Operating Temperature Range: -40 to 65°C
Storage Temperature Range: -40 to 85°C
Relative Humidity: 0 to 90% non-condensing.
Connections: Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adapters
Enclosure: 1/8 DIN, high impact plastic, UL 94V-0, color: black
Mounting: 1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm). Two panel mounting bracket assemblies are provided
Tightening Torque: Screw terminal connectors: 5 lb-in (0.56 Nm)
Overall Dimensions: 4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm) (W x H x D)
Weight: 9.5 oz (269 g)
UL File Number: UL & c-UL Listed. E160849; 508 Industrial Control Equipment
Warranty: 3 years parts & labor
Process Input
Inputs: Field selectable: 0-20, 4-20 mA, ±10 VDC (0-5, 1-5, 0-10 V), Modbus PV (slave)Accuracy: ±0.03% of calibrated span ±1 count, square root & programmable exponent accuracy range: 10-100% of calibrated span
Temperature Drift: 0.005% of calibrated span/°C max from 0 to 65°C ambient, 0.01% of calibrated span/°C max from -40 to 0°C ambient
Math Function: Linear, square root, programmable exponent, or round horizontal tank volume calculation
Multi-Point Linearization: 2 to 32 points for PV or PV1. 2 to 8 points for PV2 (Dual-Scale Level feature)
Programmable Exponent: 1.0001 to 2.9999
Low-Flow Cutoff: 0-999999 (0 disables cutoff function)
Decimal Point: Up to five decimal places or none: d.ddddd, dd.dddd, ddd.ddd, dddd.dd, ddddd.d, or dddddd
Calibration Range: 4-20 mA: minimum span input 1 & input 2: 0.15 mA. ±10 V: minimum span input 1 & 2: 0.10 V. An Error message will appear if input 1 and input 2 signals are too close together.
Input Impedance: Voltage ranges: greater than 1 MΩ. Current ranges: 50 - 100 Ω (depending on resettable fuse impedance)
Input Overload: Current input protected by resettable fuse, 30 VDC max. Fuse resets automatically after fault is removed
Relays
Rating: 2 or 4 SPDT (Form C) internal and/or 4 SPST (Form A) external; rated 3 A @ 30 VDC and 125/250 VAC resistive load; 1/14 HP (approx. 50 watts) @ 125/250 VAC for inductive loads such as contactors, solenoids, etc.Noise Suppression: Noise suppression is recommended for each relay contact switching inductive loads
Deadband: 0-100% of span, user programmable
High or Low Alarm: User may program any alarm for high or low trip point. Unused alarm LEDs and relays may be disabled (turned off)
Relay Operation: automatic (non-latching), latching (requires manual acknowledge), sampling (based on time), pump alternation control (2 to 8 relays), Off (disable unused relays and enable interlock feature, manual on/off control mode).
Relay Reset: User selectable via front panel buttons or digital inputs
1. Automatic reset only (non-latching), when input passes the reset point
2. Automatic + manual reset at any time (non-latching)
3. Manual reset only, at any time (latching)
4. Manual reset only after alarm condition has cleared (latching)
Note: Front panel button or digital input may be assigned to acknowledge relays programmed for manual reset
Time Delay: 0 to 999.9 seconds, on & off relay time delays. Programmable and independent for each relay
Fail-Safe Operation: Programmable and independent for each relay
Note: Relay coil is energized in non-alarm condition. In case of power failure, relay will go to alarm state
Auto Initialization: When power is applied to the meter, relays will reflect the state of the input to the meter
Serial Communications
Protocol: Modbus® RTUMeter Address/Slave ID: 1 - 247
Baud Rate: 300 - 19,200 bps
Transmit Time Delay: Programmable between 0 and 199 ms or transmitter always on for RS-422 communication
Data: 8 bit (1 start bit, 1 or 2 stop bits)
Parity: Even, odd, or none with 1 or 2 stop bits
Byte-to-Byte Timeout: 0.01 - 2.54 seconds
Turn Around Delay: Less than 2 ms (fixed)
Note: Refer to the PD6000/PD7000 Modbus Register Tables for details
Isolated 4-20 mA Transmitter Output
Output Source: Process variable (PV), max, min, set points 1-8, manual control setting, or Modbus inputScaling Range: 1.000 to 23.000 mA for any display range
Calibration: Factory calibrated: 4.000 to 20.000 = 4-20 mA output
Analog Output Programming: 23.000 mA maximum for all parameters: Overrange, underrange, max, min, and break
Accuracy: ± 0.1% FS ±0.004 mA
Temperature Drift: 0.4 µA/°C max from 0 to 65°C ambient, 0.8 µA/°C max from -40 to 0°C ambient
Note: Analog output drift is separate from input drift.
Isolated Transmitter Power Supply: Terminals I+ & R: 24 VDC ± 10% @ 40 mA maximum, may be used to power the 4-20 mA output or other devices. Present on both AC & DC powered units.
External Loop Power Supply: 35 VDC maximum
Output Loop Resistance:
| Power supply | Minimum | Maximum |
| 24 VDC | 10Ω | 700Ω |
| 35 VDC (external) | 100Ω | 1200Ω |
Digital I/O Expansion Module
Channels: 4 digital inputs & 4 digital outputs per moduleSystem: Up to 2 modules for a total of 8 inputs & 8 outputs
Digital Input Logic: High: 3 to 5 VDC Low: 0 to 1.25 VDC
Digital Output Logic: High: 3.1 to 3.3 VDC Low: 0 to 0.4 VDC
Source Current: 10 mA maximum
Sink Current: 1.5 mA minimum
+5 V Terminal: To be used as pull-up for digital inputs only
4-Relay Expansion Module
Relays: (4) Form A (SPST) rated 3 A @ 30 VDC and 125/250 VAC resistive load; 1/14 HP (approx. 50 watts) @ 125/250 VAC for inductive loadsMOUNTING DIMENSIONS
1. Panel cutout required: 1.772" x 3.622" (45mm x 92mm)
2. Panel thickness: 0.040 - 0.250" (1.0mm - 6.4mm)
3. Mounting brackets lock in place for easy mounting
4. Clearance: Allow 6" (152 mm) behind the panel.
ORDERING INFORMATION |
|||||||
ProVu PD6000: Standard Display |
|||||||
| Model | Description | ||||||
| PD6000-6R0 |
ProVu Dual-Line 6-Digit Process Meter; No Options Installed; Powered from 85-265 VAC | ||||||
| PD6000-6R2 |
ProVu Dual-Line 6-Digit Process Meter; 2 Relays; Powered from 85-265 VAC | ||||||
| PD6000-6R3 |
ProVu Dual-Line 6-Digit Process Meter; 4-20 mA Output; Powered from 85-265 VAC | ||||||
| PD6000-6R4 |
ProVu Dual-Line 6-Digit Process Meter; 4 Relays; Powered from 85-265 VAC | ||||||
| PD6000-6R5 |
ProVu Dual-Line 6-Digit Process Meter; 2 Relays + 4-20 mA Output; Powered from 85-265 VAC | ||||||
| PD6000-6R7 |
ProVu Dual-Line 6-Digit Process Meter; 4 Relays + 4-20 mA Output; Powered from 85-265 VAC | ||||||
| PD6000-7R0 | ProVu Dual-Line 6-Digit Process Meter; No Options; Powered from 12-24 VDC | ||||||
| PD6000-7R2 | ProVu Dual-Line 6-Digit Process Meter; 2 Relays; Powered from 12-24 VDC | ||||||
| PD6000-7R3 | ProVu Dual-Line 6-Digit Process Meter; 4-20 mA Output; Powered from 12-24 VDC | ||||||
| PD6000-7R4 | ProVu Dual-Line 6-Digit Process Meter; 4 Relays; Powered from 12-24 VDC | ||||||
| PD6000-7R5 | ProVu Dual-Line 6-Digit Process Meter; 2 Relays + 4-20 mA Output; Powered from 12-24 VDC | ||||||
| PD6000-7R7 | ProVu Dual-Line 6-Digit Process Meter; 4 Relays + 4-20 mA Output; Powered from 12-24 VDC | ||||||
ProVu PD6000: SunBright Display |
|||||||
| Model | Description | ||||||
| PD6000-6H0 |
ProVu SunBright Display Dual-Line 6-Digit Process Meter; No Options Installed; Powered from 85-265 VAC | ||||||
| PD6000-6H2 |
ProVu SunBright Display Dual-Line 6-Digit Process Meter; 2 Relays; Powered from 85-265 VAC | ||||||
| PD6000-6H3 |
ProVu SunBright Display Dual-Line 6-Digit Process Meter; 4-20 mA Output; Powered from 85-265 VAC | ||||||
| PD6000-6H4 |
ProVu SunBright Display Dual-Line 6-Digit Process Meter; 4 Relays; Powered from 85-265 VAC | ||||||
| PD6000-6H5 |
ProVu SunBright Display Dual-Line 6-Digit Process Meter; 2 Relays + 4-20 mA Output; Powered from 85-265 VAC | ||||||
| PD6000-6H7 |
ProVu SunBright Display Dual-Line 6-Digit Process Meter; 4 Relays + 4-20 mA Output; Powered from 85-265 VAC | ||||||
| PD6000-7H0 | ProVu SunBright Display Dual-Line 6-Digit Process Meter; No Options; Powered from 12-24 VDC | ||||||
| PD6000-7H2 | ProVu SunBright Display Dual-Line 6-Digit Process Meter; 2 Relays; Powered from 12-24 VDC | ||||||
| PD6000-7H3 | ProVu SunBright Display Dual-Line 6-Digit Process Meter; 4-20 mA Output; Powered from 12-24 VDC | ||||||
| PD6000-7H4 | ProVu SunBright Display Dual-Line 6-Digit Process Meter; 4 Relays; Powered from 12-24 VDC | ||||||
| PD6000-7H5 | ProVu SunBright Display Dual-Line 6-Digit Process Meter; 2 Relays + 4-20 mA Output; Powered from 12-24 VDC | ||||||
| PD6000-7H7 | ProVu SunBright Display Dual-Line 6-Digit Process Meter; 4 Relays + 4-20 mA Output; Powered from 12-24 VDC | ||||||
Enclosures |
|||||||
|
|||||||
| Model | Description | ||||||
| PDA2302 | Economical Plastic NEMA 4X Enclosure for 2 Type A, B, C, or E Meters | ||||||
| PDA2303 | Economical Plastic NEMA 4X Enclosure for 3 Type A, B, C, or E Meters | ||||||
| PDA2304 | Economical Plastic NEMA 4X Enclosure for 4 Type A, B, C, or E Meters | ||||||
| PDA2305 | Economical Plastic NEMA 4X Enclosure for 5 Type A, B, C, or E Meters | ||||||
| PDA2306 | Economical Plastic NEMA 4X Enclosure for 6 Type A, B, C, or E Meters | ||||||
| PDA2307 | Economical Plastic NEMA 4X Enclosure for 7 Type A, B, C, or E Meters | ||||||
| PDA2308 | Economical Plastic NEMA 4X Enclosure for 8 Type A, B, C, or E Meters | ||||||
| PDA2309 | Economical Plastic NEMA 4X Enclosure for 9 Type A, B, C, or E Meters | ||||||
| PDA2310 | Economical Plastic NEMA 4X Enclosure for 10 Type A, B, C, or E Meters | ||||||
| PDA2312 | Economical Plastic NEMA 4X Enclosure for 2 Type A, B, C, or E Meters | ||||||
| PDA2322 | Economical Plastic NEMA 4X Enclosure for 1 Type D + 1 Type C Meter | ||||||
| PDA2407 | Plastic NEMA 4X Enclosure for 1 Meter (Any Type) | ||||||
| PDA2411 | Plastic NEMA 4X Enclosure for 2 Meter (Any Type) | ||||||
| PDA2414 | Plastic NEMA 4X Enclosure for 1 Type D + 1 Type A, B, C or E Meter | ||||||
| PDA2504 | Plastic NEMA 4X Enclosure for 4 Type A, B, C, or E Meters | ||||||
| PDA2505 | Plastic NEMA 4X Enclosure for 5 Type A, B, C, or E Meters | ||||||
| PDA2506 | Plastic NEMA 4X Enclosure for 6 Type A, B, C, or E Meters | ||||||
| PDA2507 | Plastic NEMA 4X Enclosure for 7 Type A, B, C, or E Meters | ||||||
| PDA2508 | Plastic NEMA 4X Enclosure for 8 Type A, B, C, or E Meters | ||||||
| PDA2509 | Plastic NEMA 4X Enclosure for 9 Type A, B, C, or E Meters | ||||||
| PDA2510 | Plastic NEMA 4X Enclosure for 10 Type A, B, C, or E Meters | ||||||
| PDA2512 | Plastic NEMA 4X Enclosure for 2 Type A, B, C, or E Meters | ||||||
| PDA2522 | Plastic NEMA 4X Enclosure for 1 Type D + 1 Type C Meter | ||||||
| PDA2604 | Stainless Steel NEMA 4X Enclosure for 4 Type A,B, C or E Meters | ||||||
| PDA2605 | Stainless Steel NEMA 4X Enclosure for 5 Type A,B, C or E Meters | ||||||
| PDA2606 | Stainless Steel NEMA 4X Enclosure for 6 Type A,B, C or E Meters | ||||||
| PDA2622 | Stainless Steel NEMA 4X Enclosure for 1 Type D + 1 Type C Meter | ||||||
| PDA2704 | Steel NEMA 4 Enclosure for 4 Type A, B, C, or E Meters | ||||||
| PDA2705 | Steel NEMA 4 Enclosure for 4 Type A, B, C or E Meters | ||||||
| PDA2706 | Steel NEMA 4 Enclosure for 5 Type A, B, C or E Meters | ||||||
| PDA2722 | Steel NEMA 4X Enclosure for 1 Type D + 1 Type C Meter | ||||||
| PDA2811 | Low-Cost Plastic NEMA 4X Enclosure for 1 Meter (Type A, B, C or E) | ||||||
| PDA2812 | Low-Cost Plastic NEMA 4X Enclosure for 2 Meters (Any type) | ||||||
| PDA2821 | Low-Cost Plastic NEMA 4X Enclosure for 1 Type D Meter + 1 Type A, B, C or E Meter | ||||||
Accessories |
|||||||
| Model | Description | ||||||
| PDA1002 | ProVu DIN Rail Mounting Kit for Two Modules | ||||||
| PDA1004 | ProVu 4 Relays Expansion Module | ||||||
| PDA1044 | ProVu 4 Digital Inputs & 4 Outputs Module | ||||||
| PDA1200 | ProVu Meter Copy Cable, 3' (0.9 m) | ||||||
| PDA1232 | ProVu RS-232 Serial Adapter | ||||||
| PDA1485 | ProVu RS-422/485 Serial Adapter | ||||||
| PDA7485-I | RS-232 to RS-422/485 Isolated Converter | ||||||
| PDA7485-N | RS-232 to RS-422/485 Non-Isolated Converter | ||||||
| PDA8232-N | USB to RS-232 Converter | ||||||
| PDA8485-I | USB to RS-422/485 Isolated Converter | ||||||
| PDA8485-N | USB to RS-422/485 Non-Isolated Converter | ||||||
| PDA9485-01 | Ethernet Serial Server | ||||||
| PDX6901 | Suppressor (snubber): 0.01µF/470Ω, | ||||||















