- CPTG
-
GOSSEN
-
瑞士富巴(HUBA)
- 美国HTM接近开关、电感...
-
美国美亚过程控制公司Me...
-
952 系列法兰型孔板流...
-
951 偏心孔板流量计(...
-
72H系列高压湿塔Acc...
-
70H系列高压湿塔Acc...
-
43H系列插入式带一体式...
-
40H系列插入式带一体式...
-
37L系列高压湿塔Acc...
-
33T系列低压型Accu...
-
25D系列法兰安装型Ac...
-
24D 系列法兰安装型A...
-
23L系列高压型,插入式...
-
22L系列高压型,插入式...
-
21T系列低压型,插入式...
-
20T系列低压型,插入式...
-
11A系列内嵌型Accu...
-
10A系列内嵌型Accu...
-
Meriam孔板流量解决...
-
ACCUTUBE流量解决...
-
MP-100KT 校准泵
-
1020 差压单元
-
952 系列法兰型孔板流...
- 物液位测量与控制
- 流量测量产品
- 过程称重与控制
-
电量测量与控制
-
COMBINE M201...
-
COMBINELINE系...
-
COMBINE 3580...
-
COMBINE 3500...
-
MZC-203回路阻抗测...
-
MRP-120系列RCD...
-
MMR-620欧姆表
-
MRU-200接地电阻和...
-
CMP2钳形表
-
TKF-13相序和电机旋...
-
TKF-12C相序测试仪
-
MIC系列绝缘电阻测试仪
-
MIE 5000电气安装...
-
MPI 5200多功能电...
-
MPI 5250多功能电...
-
COMBINE 1414...
-
COMBINE 1007...
-
COMBINE 1005...
-
COMBINE 1312...
-
COMBINE 31XX...
-
COMBINE M201...
-
液体分析与控制
-
浊度测量控制仪
-
PH和电余氯测量控制仪
- 电导率测量控制仪
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
浊度测量控制仪
-
气体分析与测量
- 过程校准器
- 室内空气质量分析仪
- 暖通燃烧分析仪
- 手持式工业排放分析仪
- 美国新星气体分析系统
- 德国汉斯(Hans He...
- 美国塞弗(safetys...
-
日本RIKEN 系列气体...
- RM-570/580 系...
- GP-641 系列控制器
- GP-146 指示报警单...
- RM-590 系列控制器
- GD-K71D型智能型半...
- GD-F77D-NT 氧...
- GD-F77D氧气(O2...
- GD-V77D-NT 可...
- GD-V77D可燃气体探...
- GD-S77DG-NT ...
- GD-S77DG有毒气体...
- GD-K77DG-NT有...
- GD-K77DG有毒气体...
- GD-K71D-NT 毒...
- GD-K71D毒性气体探...
- GD-K7DII 吸入式...
- GD-D5C 吸入式可燃...
- GD-D8 吸入式可燃气...
- RI-215系列 红外线...
- GD-F44 扩散式氧气...
-
丙烯酸丁酯探测器
-
异丙醇气体探测器
-
磷化氢气体探测器
-
氢氰酸气体探测器
-
硫化氢气体探测器
-
正己烷气体探测器
-
硅甲烷气体探测器
-
氯化氢气体探测器
-
环氧乙烷探测器
-
乙酸乙酯探测器
-
六氟化硫探测器
-
四氟化碳探测器
- 压力测量与控制
-
温度测量与控制
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
阀门及气电转换产品
-
TOKO东控阀门(原装进...
- V-6850系列陶瓷碟型...
- V-6500C系列高压小...
- V-6420系列浮筒式单...
- T-8710系列钽材波纹...
- T-8660系列Y型先导...
- T-8320系列小型三通...
- T-8050系列小型全塑...
- T-5705系列高压波纹...
- T-5675系列衬胶可分...
- T-8960系列直通波纹...
- T-8950系列角形波纹...
- T-8940系列隔膜角型...
- T-8930系列一体三通...
- T-8910系列分体角型...
- T-8900系列分体直通...
- R-2000系列衬胶滚筒...
- V-5514系列金属密封...
- V-5513系列PTFE...
- V-5512系列橡胶密封...
- V-5510系列双偏心蝶...
- AKO系列管夹阀
-
美国COMBINE执行机...
- YT-405型保位阀
- YT-300型气动放大器
- AS3000-02型速度...
- SR/AW30型过滤减压...
- ITS300型角行程防爆...
- ITS100型角行程限位...
- 1Lx7001型直行程防...
- WLGCA2型直行程限位...
- M15G-8型两位五通电...
- M00U-8型两位三通电...
- 3760型小型内藏式阀门...
- YVP-110型数字式阀...
- IP-8001型HART...
- TP-601型气/气阀门...
- TP-351型电/气阀门...
- CMC-103电动式执行...
- CMS-020/040电...
- PSN系列高性能电子式伺...
- MSP系列小型电子式执行...
- C-25系列汽缸式执行机...
- 美国COMBINE电气转...
-
德国西门子SIEMENS...
- 771系列电气转换器Cu...
- 77 系列电气转换器Cu...
- 73N-B1内置式阀门定...
- 73N-B内置式阀门定位...
- 73N-FR内置式阀门定...
- 73N24F内置式阀门定...
- 73N12F内置式阀门定...
- 74-SN1阀门定位器 ...
- 74-SG1阀门定位器 ...
- 760P6阀门定位器 V...
- 760P5阀门定位器 V...
- 760P4阀门定位器 V...
- 760P2阀门定位器 V...
- 760P1阀门定位器 V...
- 760E1阀门定位器 V...
- 2306系列仪表空气过滤...
- 91-HF系列过滤减压阀...
- 661带偏压 的放大继电...
- 66 放大和减小继电器A...
- 63SDL常数差流量控制...
- 芬兰Larox 阀门(管...
-
TOKO东控阀门(原装进...
- 便携式检测仪器
- 系统与集成
- 美国诺南RONAN公司测...
- 美国ELECTROSWI...
- 美国PRECISION系...
- 瑞士Rotronic温湿...
产品资料
简单介绍:
Pulse, Open Collector, NPN, PNP, TTL, Switch Contact,
Sine Wave (Coil), Square Wave, Opto-Isolated Inputs
Isolated 4-20 mA Output for Rate or Total
5-Digit Rate, 0.7" (17.8 mm)
7 Alphanumeric Chara
详情介绍:
![]() |
![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
FEATURES
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
OVERVIEWThe ProtEX-RT PD6830 is a rugged, explosion-proof pulse input rate/ totalizer fully featured for demanding applications in hazardous areas or in the harshest environmental conditions. It is programmed using the four SafeTouch™ through-glass buttons, without removing the cover. The numeric rate display will read up to 99999 and the alphanumeric total/tag display will read up to 9999999. The alphanumeric display can also be programmed to show any combination of numbers and letters up to seven characters long for use as engineering units and/or the process identification tag. The backlight makes the display visible under any lighting condition. The enclosure is provided with threaded conduit holes and integrated pipe or wall mounting slotted flanges.![]() KEY FEATURESUser Friendly DisplayThe high contrast 0.7" high 5-digit LCD on the upper display is easy to read. The 0.4" 7-character lower display is alphanumeric and allows for more sensible looking tags, engineering units, or legends than a 7-segment display. For dark areas, the backlight (standard) can be illuminated either via output loop power (BTA & CTB), external 9 to 30 VDC (APO & APA), or battery (BMO).Through-Glass SafeTouch™ ButtonsExceptional Enclosure![]() Wide Viewing Angle The copper-free (0.3%), smooth cast aluminum NEMA 4X enclosure is finished with a corrosion resistant epoxy coating. This provides a durable finish, and helps make it an attractive looking enclosure. The built-in mounting flanges are convenient for wall or pipe mounting (up to 2½" pipes). The enclosure is provided with three ¾" NPT threaded conduit holes. The window and display module on the PD6830 enclosure have been optimized to provide a wide viewing angle of approximately +/- 40°, nearly twice the competition! This makes it even easier for operators to see the display. Environmentally Tough![]() Alarm IndicationThe PD6830 can be configured to have a high or low rate alarm indicator, or a total alarm set point indicator. When in alarm mode, the display will flash, and a HI or LO symbol is displayed. The alarm is acknowledged by pressing the ENTER/ACK button.![]()
The PD6830 is designed to handle a wide variety |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||
|
||||||||||||||||||||||||
DIMENSIONS

SPECIFICATIONS
Except where noted all specifications apply to operation at +25°C.General
Display: Five digits (-9999 to 99999) 0.70" (17.8 mm) high, 7-segment, automatic lead zero blanking. Seven characters (Alphanumeric Engineering Units) 0.4" (10.2 mm) high, 14 segment. Symbols: HI, LO, & SET Alarm, Password Lock.Backlight: White LED, 10 sec auto-off for battery powered models.
Display Update Rate: Ambient > -25°C: 2 Updates/Second. Ambient < -25°C: 1 Update/5 Seconds
Overrange: Display flashes 99999
Underrange: Display flashes -9999
Programming Method: Four SafeTouch™ through-glass buttons when cover is installed. Four internal pushbuttons when cover is removed.
Recalibration: Calibrated at the factory to read frequency in Hz. No recalibration required.
Max/Min Display: Max/Min readings reached by the process are stored until reset by the user or until power to the meter is cycled.
Password: Programmable password restricts modification of programmed settings and manual total reset via button interface.
Alarm Indication: Flashing display plus HI/LO indicators
Non-Volatile Memory: All programmed settings and total are stored in non-volatile memory for a minimum of ten years if power is lost.
Power Options: 9-30 VDC, 2.2 W max, 4-20 mA transmitter output power, 30 VDC max, battery power, or DC power with battery backup.
Battery: 3.6 V Primary Lithium (Li-SOCl2), non-rechargeable. Expected service life is 5 years. Recommended replacement interval: 3 years when exclusive source, up to 20 years in backup configuration. Model PDABAT36D.
Isolation: All models: 500 V opto-isolated input-to-power/output.
PD6830-BTA: 500 V input-to-output.
PD6830-APA: 500 V input/power-to-output
Note: Requires separate output supply
Operating Temperature Range: -40 to 75°C. (-20 to 75°C on battery powered models).
Storage Temperature Range: -40 to 75°C.
Relative Humidity: 0 to 90% non-condensing
Connections: Screw terminals accept 12 to 22 AWG wire
Enclosure: Explosion-proof die-cast aluminum with glass window, corrosion resistant epoxy coating, color: blue. NEMA 4X, 7, & 9, IP68. Copper-free (0.3%). Three ¾" NPT threaded conduit openings. One ¾" NPT metal plug with 12 mm hex key fitting installed.
Mounting: May be mounted directly to conduit. Two slotted flanges for wall mounting or NPS 1½" to 2½" or DN 40 to 65 mm pipe mounting.
Overall Dimensions: 5.65" x 5.25" x 4.86" (W x H x D) 144 mm x 133 mm x 124 mm)
Weight: 5.00 lbs (80 oz, 2.27 kg)
Warranty: 3 years parts and labor
Rate Input
Pulse Input: Field selectable; Sourcing or sinking pulse or square wave 0-5V, 0-12 V, or 0-24 V; TTL; NPN or PNP transistor; Open collector 100k Ω pull-up to 3 V; Switch contact 100k Ω pull-up to 3 V; PNP transistor 100k Ω pull-down to ground (COM). Maximum Frequency: 30 kHz. Minimum Pulse Width: 16 µsOpto-Isolated Input: Sourcing pulse or square wave 0-5 V, 0-12 V, or 0-24 V; Logic High: 4-30 V, Logic Low: < 1 V. Maximum Frequency: 10 kHz Minimum Pulse Width: 50 µs. Input Current: 1 mA @ 5 V, 2.5 mA @ 12 V, 5 mA @ 24 V
Low Voltage Mag Pickup Input: Sensitivity: 40 mVp-p to 24 Vp-p.
Maximum Frequency: 30 kHz
Minimum Input Frequency: 0.001 Hz. Minimum frequency is dependent on high gate setting.
Input Impedance: Pulse input: Greater than 300k Ω @ 1 kHz.
Open collector/switch input: 100k Ω pull-up to 3 V.
Accuracy: ±0.03% of calibrated span ± count
Temperature Drift: Rate display is not affected by changes in temperature.
Low-Flow Cutoff: 0-99999 (0 disables cutoff function)
Decimal Point: Up to five decimal places or none: d.dddd, d.ddd, d.dd, d.d, or dddddd
Calibration: May be calibrated using K-Factor, scale without signal source, or by applying an external calibration signal.
K-Factor: Field programmable K-Factor converts input pulses to rate in engineering units. May be programmed from 0.00001 to 9999999 pulses/unit.
Calibration Range: Input 1 signal may be set anywhere in the range of the meter; input 2 signal may be set anywhere above or below input 1 setting. Minimum input span is 10 Hz. An error message will appear if the input 1 and input 2 signals are too close together.
Contact Debounce Filter: Select low speed: 40 Hz maximum input frequency
Time Base: Second, minute, hour, or day
Gate: Low gate: 1-99 seconds; High gate: 2-999 seconds
Rate/Totalizer
Display Assignment: The Top display is assigned to rate. The Bottom display is programmable to alternate between total for 10 seconds, then the tag for 2 seconds or to show only the total or to show only the tag.Total Decimal Point: Up to six decimal places or none: d.dddddd, d.ddddd, d.dddd, d.ddd, d.dd, d.d or ddddddd. Total decimal point is independent of rate decimal point.
Totalizer: Calculates total based on rate and field programmable multiplier to display total in engineering units. Time base must be selected according to the time units in which the rate is displayed.
Total Reset: Via SafeTouch™ RESET button, mechanical button (cover off), external contact closure, or automatically via user selectable preset value and time delay. Manual reset may be disabled or protected by password.
Totalizer Rollover: Totalizer rolls over when display exceeds 9,999,999
4-20 mA Transmitter Output
Output Source: Rate/process or totalScaling Range: 4.000 to 20.000 mA for any display range.
Calibration: Factory calibrated: 0.0 to 1000.0 = 4-20 mA output
Underrange: 3.8 mA
Overrange: 20.5 mA
Accuracy: ±0.1% FS ±0.004 mA
Temperature Drift: 0.4 µA/°C max from 0 to 65°C ambient, 0.8 µA/°C max from -40 to 0°C ambient
Note: Analog output drift is separate from input drift.
External Loop Power Supply: 30 VDC maximum
Output Loop Resistance:
| Voltage Range | Minimum | ||||
| 24 VDC | 10 Ω | 700 Ω | |||
| 30 VDC | 100 Ω | 1200 Ω | |||
Product Ratings & Approvals
FM: Explosion-proof for use in Class I, Division 1, Groups B, C, D. Class II, Division 1, Groups E, F, G. Class III, Division 1; T6. Class I, Zone 1, AExd IIC T6 Gb. Zone 21, AEx tb IIIC T85°C. Ta = -40 to 75°C.Enclosure: Type 4X & IP66. Certificate number: 3040391
ATEX: II 2 G D. Ex d IIC T6 Gb. Ex tb IIIC T85°C Db IP68. Ta = -40 to 75°C. Certificate number: Sira 10ATEX1116X
IECEx: IECEx SIR 10.0056X. Ex d IIC T6 Gb. Ex tb IIIC T85°C Db IP68.Ta = -40°C to +75°C
CSA: Enclosure: Type 4X & IP66. Class I, Division 1, Groups B, C, D. Class II, Division 1, Groups E, F, G. Class III, Division 1; T6 Class I, Zone 1, Ex d IIC T6. Ta = -40°C to +75°C Certificate number: 11 2325749
ORDERING INFORMATIONProducts |
|||||
| Model | Description | ||||
| PD6830-BM0 | Dual-Line Explosion-Proof Rate/Totalizer Pulse Input + Backlight; Powered from Battery and 9-30 VDC | ||||
| PD6830-BTA | Dual-Line Explosion-Proof Rate/Totalizer Pulse Input with Output Loop-Powered Backlight + Loop Output; Powered from Battery and 9-30 VDC | ||||
| PD6830-AP0 | Dual-Line Explosion-Proof Rate/Totalizer Pulse Input + Backlight; Powered from 9-30 VDC | ||||
| PD6830-APA | Dual-Line Explosion-Proof Rate/Totalizer Pulse Input with Backlight + Loop Output; Powered from 9-30 VDC | ||||
| PD6830-CTB | Dual-Line Explosion-Proof Rate/Totalizer Pulse Input with Backlight + Loop Output; Powered by Output Loop | ||||
Accessories |
|||||
| Model | Description | ||||
| PDABAT36D | Approved Replacement Battery | ||||
| PDA75PLUG | Metal Stopping Plug with Approvals | ||||















>




