- CPTG
-
GOSSEN
-
瑞士富巴(HUBA)
- 美国HTM接近开关、电感...
-
美国美亚过程控制公司Me...
-
952 系列法兰型孔板流...
-
951 偏心孔板流量计(...
-
72H系列高压湿塔Acc...
-
70H系列高压湿塔Acc...
-
43H系列插入式带一体式...
-
40H系列插入式带一体式...
-
37L系列高压湿塔Acc...
-
33T系列低压型Accu...
-
25D系列法兰安装型Ac...
-
24D 系列法兰安装型A...
-
23L系列高压型,插入式...
-
22L系列高压型,插入式...
-
21T系列低压型,插入式...
-
20T系列低压型,插入式...
-
11A系列内嵌型Accu...
-
10A系列内嵌型Accu...
-
Meriam孔板流量解决...
-
ACCUTUBE流量解决...
-
MP-100KT 校准泵
-
1020 差压单元
-
952 系列法兰型孔板流...
- 物液位测量与控制
- 流量测量产品
- 过程称重与控制
-
电量测量与控制
-
COMBINE M201...
-
COMBINELINE系...
-
COMBINE 3580...
-
COMBINE 3500...
-
MZC-203回路阻抗测...
-
MRP-120系列RCD...
-
MMR-620欧姆表
-
MRU-200接地电阻和...
-
CMP2钳形表
-
TKF-13相序和电机旋...
-
TKF-12C相序测试仪
-
MIC系列绝缘电阻测试仪
-
MIE 5000电气安装...
-
MPI 5200多功能电...
-
MPI 5250多功能电...
-
COMBINE 1414...
-
COMBINE 1007...
-
COMBINE 1005...
-
COMBINE 1312...
-
COMBINE 31XX...
-
COMBINE M201...
-
液体分析与控制
-
浊度测量控制仪
-
PH和电余氯测量控制仪
- 电导率测量控制仪
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
浊度测量控制仪
-
气体分析与测量
- 过程校准器
- 室内空气质量分析仪
- 暖通燃烧分析仪
- 手持式工业排放分析仪
- 美国新星气体分析系统
- 德国汉斯(Hans He...
- 美国塞弗(safetys...
-
日本RIKEN 系列气体...
- RM-570/580 系...
- GP-641 系列控制器
- GP-146 指示报警单...
- RM-590 系列控制器
- GD-K71D型智能型半...
- GD-F77D-NT 氧...
- GD-F77D氧气(O2...
- GD-V77D-NT 可...
- GD-V77D可燃气体探...
- GD-S77DG-NT ...
- GD-S77DG有毒气体...
- GD-K77DG-NT有...
- GD-K77DG有毒气体...
- GD-K71D-NT 毒...
- GD-K71D毒性气体探...
- GD-K7DII 吸入式...
- GD-D5C 吸入式可燃...
- GD-D8 吸入式可燃气...
- RI-215系列 红外线...
- GD-F44 扩散式氧气...
-
丙烯酸丁酯探测器
-
异丙醇气体探测器
-
磷化氢气体探测器
-
氢氰酸气体探测器
-
硫化氢气体探测器
-
正己烷气体探测器
-
硅甲烷气体探测器
-
氯化氢气体探测器
-
环氧乙烷探测器
-
乙酸乙酯探测器
-
六氟化硫探测器
-
四氟化碳探测器
- 压力测量与控制
-
温度测量与控制
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
阀门及气电转换产品
-
TOKO东控阀门(原装进...
- V-6850系列陶瓷碟型...
- V-6500C系列高压小...
- V-6420系列浮筒式单...
- T-8710系列钽材波纹...
- T-8660系列Y型先导...
- T-8320系列小型三通...
- T-8050系列小型全塑...
- T-5705系列高压波纹...
- T-5675系列衬胶可分...
- T-8960系列直通波纹...
- T-8950系列角形波纹...
- T-8940系列隔膜角型...
- T-8930系列一体三通...
- T-8910系列分体角型...
- T-8900系列分体直通...
- R-2000系列衬胶滚筒...
- V-5514系列金属密封...
- V-5513系列PTFE...
- V-5512系列橡胶密封...
- V-5510系列双偏心蝶...
- AKO系列管夹阀
-
美国COMBINE执行机...
- YT-405型保位阀
- YT-300型气动放大器
- AS3000-02型速度...
- SR/AW30型过滤减压...
- ITS300型角行程防爆...
- ITS100型角行程限位...
- 1Lx7001型直行程防...
- WLGCA2型直行程限位...
- M15G-8型两位五通电...
- M00U-8型两位三通电...
- 3760型小型内藏式阀门...
- YVP-110型数字式阀...
- IP-8001型HART...
- TP-601型气/气阀门...
- TP-351型电/气阀门...
- CMC-103电动式执行...
- CMS-020/040电...
- PSN系列高性能电子式伺...
- MSP系列小型电子式执行...
- C-25系列汽缸式执行机...
- 美国COMBINE电气转...
-
德国西门子SIEMENS...
- 771系列电气转换器Cu...
- 77 系列电气转换器Cu...
- 73N-B1内置式阀门定...
- 73N-B内置式阀门定位...
- 73N-FR内置式阀门定...
- 73N24F内置式阀门定...
- 73N12F内置式阀门定...
- 74-SN1阀门定位器 ...
- 74-SG1阀门定位器 ...
- 760P6阀门定位器 V...
- 760P5阀门定位器 V...
- 760P4阀门定位器 V...
- 760P2阀门定位器 V...
- 760P1阀门定位器 V...
- 760E1阀门定位器 V...
- 2306系列仪表空气过滤...
- 91-HF系列过滤减压阀...
- 661带偏压 的放大继电...
- 66 放大和减小继电器A...
- 63SDL常数差流量控制...
- 芬兰Larox 阀门(管...
-
TOKO东控阀门(原装进...
- 便携式检测仪器
- 系统与集成
- 美国诺南RONAN公司测...
- 美国ELECTROSWI...
- 美国PRECISION系...
- 瑞士Rotronic温湿...
产品资料
简单介绍:
Description: Process & Temperature Meter
Process Inputs: 0-20 mA, 4-20 mA, 1-5 V, -10 to 10 V
Temperature Inputs: J, K, T, E TC; 100 Ω Pt RTD
Display: 1.20" (30.5 mm) Red LED 4-Digit
Case: 1/8 DIN, Hi
详情介绍:
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Features
|
![]() ![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
FEATURE RICH AND SIMPLE TO USEThe Model PD765 Trident digital panel meter is one of the most versatile digital panel meters on the market and will satisfy a wide variety of process applications. The Trident can be field programmed to accept process voltage (0-5V, 1-5V, etc) and current (4-20 mA) inputs, 100 Ohm RTDs, and the four most common thermocouples. It is housed in a shallow-depth, 1/8 DIN enclosure that features a NEMA 4X front panel and convenient mounting hardware. There are two power options for the Trident: 85 to 265 VAC or 12-36 VDC and it can provide 24 VDC to power the transmitter if needed. Programming and setup can be performed with the four front panel pushbuttons, free MeterView software, or using the Copy function. TWO DISPLAY SIZES The display height on the standard Trident meter is 0.56"(14.2 mm) and on the Trident X2 the display height is an astounding 1.2" (30.5 mm). The Trident X2 can be read easily from distances of up to 30 feet! Both meters are available with all Trident features. The intensity of the display on both versions of the Trident can be adjusted to compensate for various lighting conditions, including direct sunlight.
VERSATILE OPERATIONLook to the Trident meter for the key features and options you want and don't worry about getting bogged down in a confusing array of things you don't need. The Trident's Max/Min function, 2 relays, 4-20 mA output, serial communication, and free Modbus RTU protocol provide all the utility you need to handle all the common applications. Maximum/MinimumTo display the maximum and minimum readings since the last reset/power-up, use the Up arrow/Max buttonPowerful Relay FunctionalityAll relay functions are set up from the front panel or from a PC running MeterView® or LabView™ software.
Pump AlternationThe Trident, in pump alternation mode, will automatically alternate two pumps:
Isolated 4-20 mA Transmitter OutputThe Trident's Isolated 4-20 mA output option converts the Trident into a transmitter with a digital display; perfect for temperature applications!Serial Communication Adapters & Converters![]() A wide variety of serial communication adapters and converters are available for the Trident meter. A serial adapter and Precision Digital’s free MeterView software allows the Trident to be programmed from a computer and to connect to a PC for data acquisition. Adapters are available for RS-232 and RS-422/485 communications. Converters are available for isolated and non-isolated RS-232 to RS-422/485 and USB to RS-422/485. Modbus RTUUse the Trident’s Modbus RTU communications to connect the Trident to a PLC, SCADA system or other digital device.EASY SETUP AND PROGRAMINGThe Trident is easily setup and programmed using the simple four-button programming method. The meter can also be programmed using a PC and Precision Digital's free MeterView software or "cloned" with the Copy function. There is only one switch on the entire meter, no jumpers, and no need to ever open the case. Programming with Four Front Panel ButtonsThe Trident’s four front panel buttons keep the user in control of the programming process. To see how simple it is to program the Trident, click here.Trident Virtual Meter
Programming From a PC with MeterView®Precision Digital’s free MeterView software allows all PD765 Trident setup parameters to be programmed from a PC and to save the configuration settings to a file for reporting or programming other meters. And since the serial adapter is an external device, one serial adapter can program an infinite number of meters!![]() The MeterView screen shot above shows how the input is selected. Notice there are tabs for Scaling, Relays/Alarms, Advanced, and Factory Values. Meter CopyThe Copy function is used to copy (or clone) all the settings from one Trident meter to other Trident meters in less than 10 seconds. The Copy function is a standard feature on all meters. The Copy feature does not require a serial communication adapter, it only requires the optional cable assembly (PDA7420), see the ordering information for complete details.![]() NEMA 4 & 4X FIELD ENCLOSURESPlastic, stainless steel, and painted steel NEMA 4X enclosures for up to 10 Trident meters.
DATA ACQUISITIONDigital Panel Meters make a great front end to a PC-based data acquisition system. They are easy to set up, can be used for a wide range of inputs, will power the transmitter, and best of all provide a local display of the process. Precision Digital has the perfect package with its Trident Digital Panel Meters, a wide selection of serial adapters and converters and free MeterView software. Data is displayed on the PC and written to a file that could then be imported into a spreadsheet or other application. Data Logging up to 100 Trident Meters![]() Sample File Generated by MeterView®![]() Great for tank level monitoring!
Process & Temperature InputsThe Trident is factory calibrated to accept 4-20 mA, ±10 VDC, type J, K, T, or E thermocouples and 100 Ω platinum RTDs. Process inputs can be scaled with or without applying an input for virtually any engineering units. Temperature inputs can be programmed to display in degrees Fahrenheit or Celsius and the type K thermocouple can display up to 2300 °F. Current & Voltage InputsSetting up the meter to accept a current or voltage input could not be easier. All setup is performed with the front panel buttons and there are no switches or jumpers to deal with.![]() Transmitter Powered by External Supply ![]() Transmitter Powered by Internal Supply (optional) Current Overload ProtectionTo protect the instrument from unexpected current overload the current input circuit contains a resettable fuse. The fuse limits the current to a safe level when it detects a fault condition, and automatically resets itself when the fault condition is removed.Thermocouple & RTD InputsSetting up the Trident to accept a thermocouple or RTD input is simply a matter of setting a switch at the rear of the case and selecting the input type from the menu. The meter accepts J, K, T, or E type thermocouples as well as two, three, or four-wire 100 Ω platinum RTDs.![]() Thermocouple and RTD Inputs Connectors Location![]() Rear View QUICK INSTALLATIONThe Trident is housed in a shallow-depth case that is designed for easy installation and servicing. The extra large front bezel is rated Type 4X, IP65. The mounting brackets are locked in place to make it easy to mount the meter in the panel. Removable screw terminal connectors make for easy and convenient wiring. Mounting Dimensions![]() Notes: 1. Panel cutout required: 1.772 x 3.622 (45 x 92) 2 Panel thickness: 0.040 – 0.250 (1.0 – 6.4) 3. Mounting brackets lock in place for easy mounting SPECIFICATIONSExcept where noted all specifications apply to operation at +25°C. GeneralDisplay: Trident: 0.56” (14.2 mm); Trident X2: 1.20” (30.5 mm) red LED, 4 digits (-1999 to 9999)Display Intensity: Eight user selectable intensity levels Front Panel: NEMA 4X, IP65; panel gasket provided Programming Methods: Four front panel buttons, cloning with Copy feature, PC with MeterView or LabVIEW software, and Modbus registers. Certified LabVIEW driver available. Noise Filter: Programmable 2 to 199 (0 will disable filter) Display Update Rate: Process/RTD: 3.7-5/sec; TC: 1.8-2.5/sec Overrange: Display flashes 9999 Underrange: Display flashes -1999 Recalibration: All inputs are calibrated at the factory; recalibration is recommended at least every 12 months. Max/Min Display: Stored until reset by user or meter is turned off. Password: Restricts modification of programmed settings. Non-Volatile Memory: Settings stored for a minimum of 10 years. Power Options: 85-265 VAC, 50/60 Hz; 90-265 VDC, 20 W max or 12-36 VDC; 12-24 VAC, 6 W max. Required Fuse: UL Recognized, 5 A max, slow-blow; up to 6 meters may share one fuse. Normal Mode Rejection: 64 dB at 50/60 Hz Isolation: 4 kV input/output-to-power line;500 V input-to-output or output-to-24 VDC supplies Operating Temperature: 0 to 65°C Storage Temperature: -40 to 85°C Relative Humidity: 0 to 90% non-condensing Connections: Power & Signal: removable screw terminal blocks accept 12 to 22 AWG. Serial: RJ11 header, standard on all meters. Enclosure: 1/8 DIN, high impact plastic, 94V-0, color; gray Weight: 9.5 oz (269 g) (including options) UL File Number: E160849; 508 Industrial Control Equipment Warranty: 3 years parts & labor Process InputsInputs: Field selectable: 0-20 mA, 4-20 mA, 1-5 V, ±10 VAccuracy: ±0.05% FS ±1 count; square root: ±0.1% FS ±2 counts Function: Linear or square root Low-Flow Cutoff: 0 to 9999 (0 disables cutoff function) Decimal Point: Up to 3 decimals: d.ddd, dd.dd, ddd.d, or dddd Calibration: Scale without signal or calibrate with signal source Calibration Range: User programmable over entire range of meter Input Impedance: Voltage range: greater than 1 M Ω, Current Range: 50-100 Ω, varies with resettable fuse impedance Input Overload: Protected by automatically resettable fuse Temperature Drift: ±50 PPM/°C Transmitter Supply: Isolated, one or two transmitter supplies P1: 24 VDC ±10% @ 200 mA max (-1 option) P1 & P2: 24 VDC ±10% @ 200 mA & 40 mA max (-2 option) Temperature InputsInputs: Factory calibrated, field selectable: type J, K, T, or E thermocouples and 100 Ω platinum RTD (0.00385 or 0.00392 curve)Resolution: 1°; type T: 1° or 0.1° Cold Junction Reference: Automatic Temperature Drift: ±2°C maximum Offset Adjustment: Programmable to ±19.9°. This parameter allows the user to apply an offset value to the temperature being displayed. Input Impedance: Greater than 100 k Ω Sensor Break: All relays and alarm status LEDs go to alarm state.
RelaysRating: 2 Form C (SPDT); rated 3 A @ 30 VDC or 3 A @ 250 VAC resistive load; 1/14 HP @ 125/250 VAC inductive loadsDeadband: 0-100% FS, user selectable High or Low Alarm: User may program any alarm for high or low Relay Operation:
Automatic Reset: Relays reset when input passes the reset point Manual Reset: Front panel button, MeterView, Modbus registers Time Delay: 0 to 199 seconds, on and off delays; programmable Fail-Safe Operation: Programmable, independent for each relay. Relay coils are energized in non-alarm condition. In case of power failure; relays will go to alarm state. Auto Initialization: When power is applied to the meter, relays will reflect the state of the input to the meter. Isolated 4-20 mA Transmitter OutputScaling Range: 1.00 to 23.00 mA; reverse scaling allowed.Calibration: Factory calibrated 4.00 to 20.00 mA Accuracy: ±0.1% FS ±0.004 mA Temperature Drift: 50 PPM/°C Note: Analog output drift is separate from input drift Isolation: 500 V input-to-output or output-to-24 VDC supplies; 4 kV output-to-power line External Power: 35 VDC maximum Output Loop Resistance:
Serial CommunicationsCompatibility: EIA-232, EIA-422, and EIA-485 with PDA7232 and PDA7422 Trident adapters.Protocol: Two selectable. PDC protocol (for use with MeterView) and Modbus RTU Meter Address: PDC protocol: 0 to 99, Modbus protocol: 1 to 247 Baud Rate: 300 to 19,200 bps Transmit Time Delay: Programmable 0 to 199 ms or transmitter always on for RS-422 communications. Data: 8 bit (1 start bit, 1 stop bit) Parity: None (2 stop bits), even, or odd (Modbus only; PDC protocol does not use parity) Byte-to-Byte Timeout: 0.01 to 2.54 seconds (Modbus only) Turn Around Delay: Less than 2 ms (fixed) Refer to PDC and Modbus Serial Communications Protocol manuals for details. Note: Both downloadable protocol register tables can be found in the documentation list below. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||

























