- CPTG
-
GOSSEN
-
瑞士富巴(HUBA)
- 美国HTM接近开关、电感...
-
美国美亚过程控制公司Me...
-
952 系列法兰型孔板流...
-
951 偏心孔板流量计(...
-
72H系列高压湿塔Acc...
-
70H系列高压湿塔Acc...
-
43H系列插入式带一体式...
-
40H系列插入式带一体式...
-
37L系列高压湿塔Acc...
-
33T系列低压型Accu...
-
25D系列法兰安装型Ac...
-
24D 系列法兰安装型A...
-
23L系列高压型,插入式...
-
22L系列高压型,插入式...
-
21T系列低压型,插入式...
-
20T系列低压型,插入式...
-
11A系列内嵌型Accu...
-
10A系列内嵌型Accu...
-
Meriam孔板流量解决...
-
ACCUTUBE流量解决...
-
MP-100KT 校准泵
-
1020 差压单元
-
952 系列法兰型孔板流...
- 物液位测量与控制
- 流量测量产品
- 过程称重与控制
-
电量测量与控制
-
COMBINE M201...
-
COMBINELINE系...
-
COMBINE 3580...
-
COMBINE 3500...
-
MZC-203回路阻抗测...
-
MRP-120系列RCD...
-
MMR-620欧姆表
-
MRU-200接地电阻和...
-
CMP2钳形表
-
TKF-13相序和电机旋...
-
TKF-12C相序测试仪
-
MIC系列绝缘电阻测试仪
-
MIE 5000电气安装...
-
MPI 5200多功能电...
-
MPI 5250多功能电...
-
COMBINE 1414...
-
COMBINE 1007...
-
COMBINE 1005...
-
COMBINE 1312...
-
COMBINE 31XX...
-
COMBINE M201...
-
液体分析与控制
-
浊度测量控制仪
-
PH和电余氯测量控制仪
- 电导率测量控制仪
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
浊度测量控制仪
-
气体分析与测量
- 过程校准器
- 室内空气质量分析仪
- 暖通燃烧分析仪
- 手持式工业排放分析仪
- 美国新星气体分析系统
- 德国汉斯(Hans He...
- 美国塞弗(safetys...
-
日本RIKEN 系列气体...
- RM-570/580 系...
- GP-641 系列控制器
- GP-146 指示报警单...
- RM-590 系列控制器
- GD-K71D型智能型半...
- GD-F77D-NT 氧...
- GD-F77D氧气(O2...
- GD-V77D-NT 可...
- GD-V77D可燃气体探...
- GD-S77DG-NT ...
- GD-S77DG有毒气体...
- GD-K77DG-NT有...
- GD-K77DG有毒气体...
- GD-K71D-NT 毒...
- GD-K71D毒性气体探...
- GD-K7DII 吸入式...
- GD-D5C 吸入式可燃...
- GD-D8 吸入式可燃气...
- RI-215系列 红外线...
- GD-F44 扩散式氧气...
-
丙烯酸丁酯探测器
-
异丙醇气体探测器
-
磷化氢气体探测器
-
氢氰酸气体探测器
-
硫化氢气体探测器
-
正己烷气体探测器
-
硅甲烷气体探测器
-
氯化氢气体探测器
-
环氧乙烷探测器
-
乙酸乙酯探测器
-
六氟化硫探测器
-
四氟化碳探测器
- 压力测量与控制
-
温度测量与控制
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
阀门及气电转换产品
-
TOKO东控阀门(原装进...
- V-6850系列陶瓷碟型...
- V-6500C系列高压小...
- V-6420系列浮筒式单...
- T-8710系列钽材波纹...
- T-8660系列Y型先导...
- T-8320系列小型三通...
- T-8050系列小型全塑...
- T-5705系列高压波纹...
- T-5675系列衬胶可分...
- T-8960系列直通波纹...
- T-8950系列角形波纹...
- T-8940系列隔膜角型...
- T-8930系列一体三通...
- T-8910系列分体角型...
- T-8900系列分体直通...
- R-2000系列衬胶滚筒...
- V-5514系列金属密封...
- V-5513系列PTFE...
- V-5512系列橡胶密封...
- V-5510系列双偏心蝶...
- AKO系列管夹阀
-
美国COMBINE执行机...
- YT-405型保位阀
- YT-300型气动放大器
- AS3000-02型速度...
- SR/AW30型过滤减压...
- ITS300型角行程防爆...
- ITS100型角行程限位...
- 1Lx7001型直行程防...
- WLGCA2型直行程限位...
- M15G-8型两位五通电...
- M00U-8型两位三通电...
- 3760型小型内藏式阀门...
- YVP-110型数字式阀...
- IP-8001型HART...
- TP-601型气/气阀门...
- TP-351型电/气阀门...
- CMC-103电动式执行...
- CMS-020/040电...
- PSN系列高性能电子式伺...
- MSP系列小型电子式执行...
- C-25系列汽缸式执行机...
- 美国COMBINE电气转...
-
德国西门子SIEMENS...
- 771系列电气转换器Cu...
- 77 系列电气转换器Cu...
- 73N-B1内置式阀门定...
- 73N-B内置式阀门定位...
- 73N-FR内置式阀门定...
- 73N24F内置式阀门定...
- 73N12F内置式阀门定...
- 74-SN1阀门定位器 ...
- 74-SG1阀门定位器 ...
- 760P6阀门定位器 V...
- 760P5阀门定位器 V...
- 760P4阀门定位器 V...
- 760P2阀门定位器 V...
- 760P1阀门定位器 V...
- 760E1阀门定位器 V...
- 2306系列仪表空气过滤...
- 91-HF系列过滤减压阀...
- 661带偏压 的放大继电...
- 66 放大和减小继电器A...
- 63SDL常数差流量控制...
- 芬兰Larox 阀门(管...
-
TOKO东控阀门(原装进...
- 便携式检测仪器
- 系统与集成
- 美国诺南RONAN公司测...
- 美国ELECTROSWI...
- 美国PRECISION系...
- 瑞士Rotronic温湿...

|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
INTRODUCTIONThe ExSense T Series is a line of rugged, smart temperature transmitters that includes models with HART communication capability. These models can be configured using a HART modem and a PC running the free HART software provided, or the range can be modified in the field using a handheld HART communicator. The other models can be configured using a USB modem and a PC running the free software provided. All models can be ordered with Pt100 RTD, J, K, T thermocouples; see Ordering Information for model numbers.PD301 - PD306 Head Mount ModelsThe head mount models are offered as: hockey-puck only (PD301 & PD302) which can be mounted inside a DIN Form B connection head, pre-mounted in a connection head (PD303 & PD304), and pre-mounted in a connection head with temperature probe (PD305 & PD306). The PD302, PD304, and PD306 include HART communication capability. Standard enclosed models have an aluminum connection head with a 1/2" NPT conduit hole and 1/2" NPT process opening for a probe or adapter fitting, and are available with safe area (NEMA 4X, IP66 rated), or Certified explosion-proof housings. Non-standard models with other conduit hole and process opening sizes, as well as an optional stainless steel housing are available, visit the ExSense Builder.PD310 & PD312 Enhanced Display ModelsThe enhanced display models, with standard loop-powered backlight, let the user see the display under any lighting condition, and present valuable information such as the process variable, input type, engineering units, and bargraph. The display can be configured to show the PV, mA output, or %. These models are housed in a sleek & rugged die-cast NEMA 4X enclosure that is available in general purpose and explosion-proof versions. The enclosure has two 1/2" NPT conduit holes, and one 1/2" NPT process sensor connection port for probe or adapter fitting. Non-standard models with other conduit hole and process opening sizes are available, see the ExSense Builder。 For remote mounting applications the PD310 may be ordered without the process sensor connection port.APPLICATIONSThe ExSense packaging lends itself for duty in harsh environments. The good looking die-cast aluminum NEMA 4X housing affords serious protection from the elements, impact damage, corrosion, and electrical interference; it is also explosion-proof. It can be installed almost anywhere. The display models have very flexible installation options. The built-in mounting ears allow for wall, or pipe mounting, and include a rotatable meter. All ExSense systems can be also surface mounted via the thermowell.![]() 330° Rotatable LCD DisplayMount the product at any convenient angle and rotate the internal display for best viewing angle.![]() PD312 HART Transmitter & Remote DisplayIn this application the Smart HART Explosion-Proof Temperature Transmitter is being powered by the PD6000 dual-scale meter; the meter displays the temperature on the top and the mA current on the bottom display. A PLC, DCS, or other devices could be connected in the loop as shown. The 250 ohm resistor is the minimum loop resistance needed for HART communication with a HART modem or a HART communicator.![]() PD306 HART Head Transmitter ExSenseView PC Software & Remote DisplayIn this application the Smart Transmitter is mounted in the explosion-proof connection head and is being powered by the PD6000 dual-scale meter. The HART communicator and HART modem are used during configuration or troubleshooting.![]() CONFIGURATIONPD301 - PD306 PC Configuration![]() PD302 HART Configuration*![]() PD310 & PD312 HART Configuration![]() * Transmitters can be completely configured using the ExSenseView PC software and modem. HART models can also be configured using a HART Communicator (with the exception of input Type and Units). ExSenseView PC Software
TRANSMITTER INPUT TYPES, RANGES, AND ACCURACY
COMPLETE TEMPERATURE ASSEMBLY Simplify your ordering process by getting a complete temperature assembly from Precision Digital. Use the online ExSense Builder to select your transmitter, temperature probe, and thermowell; specify the temperature range and you will get all the parts needed for your temperature system. Avoid the headaches of getting components that do not match, from different suppliers. Order a complete temperature assembly from Precision Digital and make your life easier. ACCESSORIESRTD Probes & Thermowells![]() RTD probes are offered in 6", 9", and 12" lengths and ¼" diameter; other sizes are available upon request. Spring-loaded probes and thermowells are special order; please consult the factory for details.
TC & RTD Connection Heads
CONNECTIONSPD301 - PD306![]() PD310 & PD312![]() DIMENSIONSPD301 & PD302![]() PD310 & PD312![]()
MOUNTING ![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SPECIFICATIONSGeneralInput: Universal RTD, TC, Resistance, or VoltagePower Supply: 7.5 to 45 VDC, reverse polarity protected Storage Temperature: -40 to 100°C Connections: Screw terminals accept 12 to 22 AWG Output: Two-wire 4-20 mA scalable Accuracy: ±0.08% of span typical, see table on page 5 for details Temperature Drift: RTD: ±0.004°C/°C; TC: ±0.03°C/°C Underrange: 3.8 mA Overrange: 20.8 mA Sensor Break: Selectable ≤3.6 mA Low Alarm or ≥22 mA High Alarm Response Time: 1 second Long Term Stability: Better than 0.05% per year Start Up Time: Less than 5 seconds Noise Filter: Configurable from 0 to 85 µA Damping Time: Configurable from 0 to 30 sec Output Resolution: 0.3 µA Non-Volatile Memory: All configured settings are stored in non-volatile memory for a minimum of ten years. Relative Humidity: 0 to 90%, condensation allowed Isolation: 2 kV input-to-output Shock & Vibration Resistance: 4g/2 to 150 Hz as per IEC 60 068-26 EMC: Immunity & emission interference according to GB/T17626.2-1998), compliance with IEC 61000-4-3:1995 Warranty: 1 year parts & labor PD310 & 312 Exp-Proof Smart TransmitterDisplay: PV: 0.3" (8 mm) 5-digit LCD, Input & Units: 0.2" (5 mm)Bargraph: 52 segments with 2% resolution Backlight: Loop-powered, always on Configuration Method: PDA8302 HART modem and PC software or range configuration with handheld HART communicator* Load Impedance: 650 Ω @ 24 VDC max or ((V supply - 10.5 V)/0.0208 A) Ω Operating Temperature: -30 to 75°C Enclosure: Explosion-proof or general purpose die-cast aluminum, 0.3% max copper content, NEMA 4X, IP66; two ½" NPT conduit holes, one ½" NPT process connection; other sizes available upon request. PD310-A2 & PD312-A2 Approvals: FM: Explosion-proof for Class I, Division 1, Groups B, C and D; dust-ignition-proof for Class II/III, Division 1, Groups E, F and G, hazardous (classified) locations, indoors and outdoors (Type 4X/IP66) CSA: Explosion-proof for Class I, Division 1, Groups B, C and D; dust-ignition-proof for Class II/III, Division 1, Groups E, F and G, hazardous (classified) locations, indoors and outdoors (Type 4X/IP66) ATEX: II 2 G D, Ex d IIC, Ex tD A21, IP68, Ta = -40°C to +85°C IECEx: Ex d IIC, Ex A21 tD, IP68, Ta = -40°C to +85°C Weight: 2.42 lb (1.10 Kg) Overall Dimensions: 4.30" x 4.27" x 3.62" (109.2 x 108.4 x 92.0) (W x H x D), probe and thermowell not included PD301 & 302 Head Mount Smart TransmitterConfiguration Method:PD301: PDA8301 USB modem and PC software PD302: PDA8301 USB or PDA8302 HART modem and PC software or range configuration with handheld HART communicator* Load Impedance: 790 Ω @ 24 VDC max or ((V supply - 7.5 V)/0.0208 A) Ω Operating Temperature: -40 to 85°C Enclosure: Polycarbonate housing with epoxy potting, NEMA 1, IP00 (NEMA 4X, IP66 with PDA1080WM) Weight: 1.18 oz (33.5 g) Overall Dimensions: Dia. 1.73" x 0.89" (44 mm x 22.5 mm) Installation Angle: No limit Installation Area: Connection head according to DIN 43 729 Form B PD303 & PD304 Head-Mounted Smart TransmitterConfiguration Method:PD303: PDA8301 USB modem and PC software PD304: PDA8301 USB or PDA8302 HART modem and PC software or range configuration with handheld HART communicator* Load Impedance: 790 Ω @ 24 VDC max or ((V supply - 7.5 V)/0.0208 A) Ω Operating Temperature: -40 to 85°C Enclosure: Aluminum or 316 SS mounting head NEMA 4X, IP66 with optional explosion-proof Certification. Note: The Certification applies to the connection head only and not to the transmitter assembly. Weight: 1.0 lb (453.6 g) Overall Dimensions: Dia. 3.5" x 4.0" (90 mm x 101.6 mm) Installation Angle: No limit Installation Area: Connection head according to DIN 43 729 Form B PD305 & PD306 Head-Mounted Smart Transmitter with Thermowell and/or ProbeConfiguration Method:PD305: PDA8301 USB modem and PC software PD306: PDA8301 USB or PDA8302 HART modem and PC software or range configuration with handheld HART communicator* Load Impedance: 790 Ω @ 24 VDC max or ((V supply - 7.5 V)/0.0208 A) Ω Operating Temperature: -40 to 85°C Enclosure: Aluminum or 316 SS mounting head NEMA 4X, IP66 with optional explosion-proof Certification Weight: 1.0 lb (453.6 g) plus probe/thermowell weight Overall Dimensions: Dia. 3.5" x 4.0" (90 mm x 101.6 mm) plus probe/thermowell length Installation Angle: No limit Installation Area: Connection head according to DIN 43 729 Form B * The Input Type and Units cannot be changed with HART Communicators (e.g. HC275, HC375). Connection HeadsMaterial: Die-cast aluminum or 316 stainless steelCertification: FM/CSA/ATEX Explosion-proof Certified, NEMA 4X, IP66 or general purpose without certification Connections: Two ½" NPT for conduit and process connection; other sizes available upon request Mounting Holes: Accept M4 screws, see dimensions drawing Surface Finishing: Aluminum: Blue epoxy coated, Stainless steel: Electropolished O-Ring: Buna-N Weight: Aluminum: 0.450 kg (1.0 lb), Stainless steel: 0.90 kg (2.0 lbs) Features: SS ball chain included, terminal block (Ceramic/Bakelite optional) Overall Dimensions: Dia. 3.5" x 4.0" (90 mm x 101.6 mm) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
ExSense Builder![]() To help build the correct model number for your application, use the online ExSense Builder. This online tool can be accessed by clicking on any of the links provided. After a transmitter type selection is made the following options are available:
Note: Standard RTD is 1/4" in diameter , stainless steel, 400°F max. For other sizes and temperature ranges, contact the factory. Once a new model is generated using the ExSense Builder, you will
Note: HART models must be configured using the ExSenseView PC software and PDA8302 HART modem. The Input Type and Units cannot be changed with HART Communicators (e.g. HC275, HC375). Go to the ExSense Builder to build a complete model number and get pricing. Example 1: PD301-C0 Head mount temperature transmitter with factory defaults Example 2: PD310-G2-C1 HART temperature transmitter with display, general purpose, custom configuration Example 3: PD312-G2-C1-P11S06-T106 PD312 = HART temperature transmitter with display & temperature probe G2 = Rugged general purpose NEMA 4X enclosure C1 = Custom configuration P11 = 100 Pt RTD with 6" leads S06 = Spring-loaded 6" probe for thermowell installation T106 = Type 1 thermowell to match 6" spring-loaded probe Example of Other Options:
![]() RTD/TC Connection Head Assembly PDA1080WM head shown with PDA8059-04-EG terminal block |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||

























