AT6101A - portable multifunctional scintillation gamma radiation spectrometer to measure gamma radiation energy distribution, evaluate gamma radioactivity of different sources geometries and perform other radiation monitoring tasks.
AT6101D - portable multifunctional scintillation gamma radiation spectrometer to measure gamma radiation energy distribution and evaluate effective specific activity of natural radionuclides in rocks, building materials and products and water without sampling.
Features

- Spectrometric smart probes with computer interface |
|
- 2-? and 4-? measuring (on surface and in holes) - AT6101D |
|
- Instrument and firmware recalibration - AT6101A |
|
- Continuous automatic LED stabilization of the energy scale and its periodical calibration using a KCl check sample |
|
- Digital temperature compensation of the measuring path |
|
- Logging up to 300 spectra |
|
- Spectrometric data readout on a backlit LCD 128x64 |
|
- Field operation |
|
- Hermetic temperature and shock proof enclosure - AT6101D |
|
Application

- Environmental monitoring |
|
- Radioactive waste monitoring |
|
- Illicit traficking of radioactive sources and materials monitoring |
|
- Radiation monitoring of building materials and products |
|
- Nuclear industry |
|
- Geological survey |
|
- Nuclear medicine |
|
- Scientific research |
|
- Emergency |
|
Specification
|
 |
 |
Scintillation detectors |
|
АТ6101A |
NaI (Tl) ? 63х63 mm |
АТ6101D |
NaI (Tl) ? 63х63 mm |
Gamma radiation detection in energy ranges |
|
АТ6101A |
20-1500 keV and 40-3000 keV |
АТ6101D |
50-3000 keV |
Integral non-linearity |
not more than 1 % |
Relative energy resolution on 137Cs |
not more than 9.5 % |
Number of channels |
512 |
Maximum input statistical load |
5·104 s-1 |
Continuois operation time |
|
built-in accumulator unit |
not less than 12 h |
Energy scale instability for continuous operation of 12 h |
not more than 1.5 % |
Intrinsic effective specific activity measurement error |
|
АТ6101D |
not more than ± 30 % |
NORM effective specific activity measuring range - АТ6101D |
|
2-? (surface) |
100 - 104 Bq/kg |
4-? (hole) |
50 - 104 Bq/kg |
Operating temperature range |
-20 - +50oC |
Relative air humidity at 35oС |
95 % |
Operation mode setup time |
not more than 10 min |
Protection class |
IP54 |
Radio disturbance |
|
CEI/IEC CISPR 22:1997 |
|
Electromagnetic compatibility |
|
CEI/IEC 61000-4-2:1995 |
|
IEC 61000-4-3:1995 |
|
Weight |
|
АТ6101А (smart probe BDKG-11) |
1.9 kg |
АТ6101D (smart probe BDKG-11 in hermetic enclosure) |
4.0 kg |
PU |
0.8 кг |
Dimensions |
|
АТ6101А (smart probe BDKG-11) |
? 80х345 mm |
АТ6101D (smart probe in hermetic enclosure) |
? 121х477 mm |
PU |
109х200х35 mm |

Complete set:
АТ6101А: spectrometric gamma radiation smart probe, processing unit, AC adapter, check sample, shoulder strap, Manual, packing case and package.
Kit of accessories to connect to PC and applied software to acquire and process spectra on PC are options and they are supplied on additional order.
АТ6101D: spectrometric gamma radiation smart probe in hermetic enclosure, processing unit, AC adapter, check sample, shoulder strap, Manual, packing case and package.
Kit of accessories to connect to PC and applied software to acquire and process spectra on PC are options and they are supplied on additional order
|