    PS71 系列压力开关
通用型微型压力开关 
 
特性...
- 10到750psi (0.7到51.7bar)
- 现场可调或工厂设定
- 在低温极限下设定点变化极小
 
概述/设计原理:
PS72系列压力开关基于多功能微动开关设计,适用于OEM客户的中等压力的应用,拥有已经证实的PS71系列的全部性能,同时还具备Kapton®的低温能力. 
| Specifications: | ||
| Operating Temperature | see table below | |
| Switch | see table below | |
| Wetted Parts | Housing: Zinc plated steel (316L stainless steel and brass available) | |
| Electrical Termination | DIN 43650A IP65; Spade Terminals IP00; Flying Leads IP65; Conduit with Flying Leads IP65; IP Option IP66 | |
| Proof Pressure | 3000 psi (207 bar) | |
| Burst Pressure | 6000 psi (414 bar) | |
| Approvals | CE, UL Approved units available, consult factory | |
| Weight, Approximate | 0.4 lbs. (0.15 kg) Steel | |
| Recommended Operating Temperature Limits* | |||
| Diaphragm Material | -A, -B, -C Circuit without -RD | -A, -B, -C Circuit with -RD | |
| Teflon Coated Kapton® | -40°F to 185°F (-40°C to 85°C) | -40°F to 250°F (-40°C to 121°C) | |
* Switches may function below the cold temperature limit, but the setpoints and deadband will increase. Consult factory for details.
| Switch Ratings | |||
| Electrical Switch Ratings | AC | DC | |
| No option or -RD | 5 amps @ 125/250 Volts | 5 amp resistive, 3 amps inductive @ 28 Volts | |
| -G or -RD with -G | 1 amp @ 125 Volts | 1 amp resistive, 0.5 amp inductive @ 28 Volts | |
| -10A or -SP without -G | 10.1 amp @ 125/250 Volts | ||
| -SP with -G | 2 amp @ 125/250 Volts | ||
| Repeatability / Deadband | |||
| Pressure Range Code | Pressure Range | Repeatability | Average Deadband* | 
| 10 | 10-30 psi (0.7 to 2.1 bar) | ± 1.5 psi (0.103 bar) + 3% of setting | 3.5 psi (0.28 bar) + 12% of setting | 
| 20 | 25-75 psi (1.7-5.2 bar) | ± 2.5 psi (0.172 bar) + 3% of setting | |
| 30 | 65-300 psi (4.5-20.7 bar) | ± 5.0 psi (0.138 bar) + 3% of setting | 20 psig (1.38 bar) + 12% of setting | 
| 40 | 250-1000 psi (17.2-69 bar) | ± 15 psi (1.03 bar) + 3% of setting | 45 psig (3.10 bar) + 13% of setting | 
*These numbers are for the standard microswitch. With either the -SP or 10A option, the values are typically 20% greater than those listed. With the -RD option, the values are typically 25% less than those listed. In certain applications, deadband can be tailored and controlled to customer specifications. Consult factory for details.
 
 
    