    PS1200 系列压力传感器
 OEM 压力传感器具有**的耐压性和超高稳定性,压力量程从真空到 6000 PSI (400 Bar)
特性... 
- 电压输出型和电流输出型
- 表压、真空及复合压力型
- 通用型及耐冲洗型外壳
- 采用厚薄膜结构,提高耐压性能
 
概述/设计原理:
1200系列压力传感器采用CVD和ASIC设计及厚薄膜结构,坚固耐用、性能稳定。厚薄膜使得传感器可以承受因泵搅动和电磁阀等引起的*大压力峰值。传感器采用模块化设计,可针对OEM应用订购特殊的配件、电缆等等。同时,ASIC和CVD技术也使Gerns可以提供几乎任何压力范围下任何输出量的产品.
应用:
- OHV(非公路车辆)
- 天然气设备
- 半导体加工
- 电站
- 制冷
- 机器人
- HVAC(暖通空调)
| 性能参数 | ||
| 输入 | ||
| 压力范围 | Vacuum to 400 bar (6000 psi) Gauge datum only | |
| 耐压 | 4 x Full Scale (FS) (<1% FS Zero Shift) | |
| 破裂压 | >35 x FS <= 4 bar (60 psi); | |
| 疲劳寿命 | Designed for more than 100 million FS cycles | |
| 性能 | ||
| 供电电源灵敏性 | 0.01% FS/Volt | |
| 长期偏移 | 0.2% FS/year (non-cumulative) | |
| 精度 | 0.5 % FS typical (optional 0.15% FS) | |
| 温度误差 | 2.0% FS typical | |
| 温度补偿 | -20°C to 80°C (-5°F to 180°F) | |
| 工作温度 | -40°C to 125°C (-22°F to 260°F) for elec. codes A, B | |
| 零点允差 | 1% of span | |
| 量程允差 | 1% of span | |
| 响应时间 | 0.5 ms | |
| 机械结构 | ||
| 压力端口 | See ordering chart | |
| 接液部件 | 17-4 PH Stainless Steel | |
| 电气连接 | See ordering chart | |
| 外壳 | 316 SS, 17-4 PH ss | |
| 振动 | 70g, peak to peak sinusoidal, 5 to 2000 Hz | |
| 加速度 | 100g steady acceleration in any direction 0.032% FS/g for 1 bar (15 psi) range decreasing logarithmically to 0.0007% FS/g for 400 bar (6000 psi) range | |
| 冲击 | 20g, 11 ms, per MIL-STD.-810E | |
| 认证 | CE, UR (12 ET, 16 ET Intrinsically safe) | |
| 重量 | Approx. 100 grams (additional; cable 75 g/m) | |
| 电压输出 | ||
| 输出 | See ordering chart | |
| 供电电压 (Vs) | 1.5 Vdc above span to 35 Vdc | |
| *小负载电阻 | (FS output / 2) K ohms | |
| 电流输出 | ||
| 输出 | 4-20 mA (2 wire) | |
| 供电电压(Vs) | 24 Vdc, (7-35 Vdc) Above 100°C supply limited to 24 Vdc | |
| *大回路负载 | (Vs-7) x 50 ohms | |
*Electromagnetic Capability
Meets the requirement for CE marking of EN50081-2 for emissions and EN50082-2 for susceptibility.
Test Data:
• EN61000-4-2 Electrostatic Discharge. 8kV air discharge, 4kV contact discharge. Unit survived.
• ENV50140 Radiated RF Susceptibility. 10V/m, 80MHz-1GHz, 1kHz mod. Maximum recorded output error was <±1%
• ENV50204 Radiated RF Susceptibility to Mobile Telephones. 10V/m, 900MHz. Maximum recorded output error was <±1%.
• EN61000-4-4 Fast Burst Transient. 2kV, 5/50ns, 5kHz for 1 minute. Unit survived.
• ENV50141 Conducted RF Susceptibility. 10Vms, 1kHz mod, 150kHz - 80MHz. Maximum recorded output error was <±1%  
 
 
    