Electric security:
    
        - measurement category: CAT III 600V acc. to EN 61010-1:2004
- protection class acc. to EN 60529: IP40
    Other technical data:
    
        - power supply: 9V battery type 6LR61
- display:  6600 counts, backlit LCD
- continuity test: threshold 40Ω; test current < 0,5mA
- diode test: test current of 0,3mA, typical open circuit voltage < 3V DC, typical
- low battery indication: BAT displayed
- over range indication: 0L displayed
- sampling rate: 2 times per second
- INRUSH: integration time 100ms
- temperature sensor: type K thermocouple
- input impedance: 10MΩ (V DC and V AC)
- AC bandwidth: 50...400Hz (A AC and V AC)
- auto power OFF: approx. 25 min.
- dimensions: 229 x 80 x 49 mm
- weight: 303 g
- accordance with following standards: EN 61010-1:2004, EN               61010-2-032       
- quality standard: ISO 9001
Rated operational conditions:
        - internal clamp diameters: d1=36mm/d2=52mm
- operating temperature: +5...+40°C
- storage temperature: -20...+60°C
- operating humidity: max 80% up to 31°C decreasing linearly to 50% at 40°C
- storage humidity: <80%
- operating altitude: max 2000 m
AC/DC current measurement (TRUE RMS) 
    
        
            
                | Range | Resolution | Accuracy (DC)
 | Accuracy (AC)
 | 
            
                | 0...659,9A | 0,1A | ±(2,5% m.v. +5 dgt) | ±(2,5% m.v + 8 dgt) for f=50...60Hz
 
 | 
            
                | 660...1000A | 1A | ±(2,8% m.v. +8 dgt) | ±(2,8% m.v. + 8 dgt) for f=50...60Hz
 
 | 
        
    
    
    
    DC voltage measurement
     
     
    
        
            
                | Range | Resolution | Accuracy 
 | 
            
                | 0...6,599V | 0,001V | ±(1,5% m.v. + 3 dgt) 
 | 
            
                | 6,60...65,99V | 0,01V | 
            
                | 66,0...1000,0V | 0,1V | 
        
    
    
    AC voltage measurement (TRUE RMS)
     
    
        
            
                | Range | Resolution | Accuracy 
 | 
            
                | 0...6,599V | 0,001V | ±(1,8% m.v. + 5 dgt) for f=50...60Hz
 
 | 
            
                | 6,60...65,99V | 0,01V | 
            
                | 66,0...1000,0V | 0,1V | 
        
    
     Resistance measurement
    
        
            
                | Range | Resolution | Accuracy | 
            
                | 0,0...659,9Ω | 0,1Ω | ±(1,0% m.v. + 4 dgt) | 
            
                | 0,660...6,599kΩ | 0,001kΩ | ±(1,5% m.v. + 2 dgt) | 
            
                | 6,60...65,99kΩ | 0,01kΩ | 
            
                | 66,0...659,9kΩ | 0,1kΩ | 
            
                | 0,660...6,599MΩ | 0,001MΩ | ±(2,5% m.v. + 3 dgt) | 
            
                | 6,60...66,00MΩ | 0,01MΩ | ±(3,5% m.v. + 5 dgt) | 
        
    
     
    Frequency measurement
    
        
            
                | Range | Resolution | Accuracy | 
            
                | 30,0...999,9Hz | 0,1Hz | ±(1.2% m.v. + 2 dgt) sensitivity:30...5kHz:10Vrms min.
 5kHz...15kHz:40Vrms min.
 for 20%...80% duty cycle
 
 | 
            
                | 1,000...9,999kHz | 0,001kHz | 
            
                | 10,00...15,00kHz | 0,01kHz | 
        
    
     
    Temperature measurement
    
        
            
                | Range | Resolution | Accuracy | 
            
                | -20...760°C | 0,1°C | ±(3,0% m.v. + 5°C) 
 | 
            
                | -4...1400°F | 0,1°F | ±(3,0% m.v. + 9°F) | 
        
    
    Duty cycle measurement
    
        
            
                | Range | Resolution | Accuracy | 
            
                | 10,0...94,9% | 0,1% | ±(1,2% m.v. + 2 dgt) | 
        
    
     
    • pulse width: 100μs...100ms,
    • frequency range: 30Hz...5kHz,
    • sensitivity: 30Hz...5kHz: 10Vrms, 5kHz...15kHz: 40Vrms.
      „m.v.”- measured value