FEATURES ::
- 2- or 4-wire FMCW technology
- TBF mode for low Er
- Digital communication
- Field indicator facility
- High accuracy up to ± 1 mm
- High pressure
- High temperature range
- Low dead band
- Explosion-proof models
APPLICATIONS ::
- Level or volume measurement
- Liquids, powders, granules with Er > 1.5
- Medium with dust, vapour or pressurized gas layers above the product surface
- Heavy industrial applications
SPECIFICATIONS ::
- Power supply: 24 V DC, 24 V AC, 100…240V AC
- Flange temperature: -60…+250 °C
- Pressure: 0….64 bar
- Measuring range: up to 40 m
- Analogue Output: 4…20 mA (active or passive)
- Communication: HART, Profibus, FF, Modbus
- Protection: IP 67
- Approval: ATEX (Ex) 1/2G IIC, 1/2D, FM, JIS
|
|