产品详情
  • 产品名称:AT1121A 便携式X射线和γ辐射剂量计

  • 产品型号:AT1121A
  • 产品厂商:阿通特斯ATOMTEX
  • 产品价格:0
  • 折扣价格:0
  • 产品文档:
你添加了1件商品 查看购物车
简单介绍:
携带式多功能大范围仪器,可作为组织等效侦测器,进行伽玛和贝他辐射源研究,环境等效剂量和剂量率量测,评定曝露时间。 ‧提供内建量测路径的LED稳定系统,不需要使用参考源。 ‧大型背光L LCD显示屏,具远程控制的量测模式,在门坎超过时声音和视觉警报。 ‧应用包括:X射线诊断、核子医学、放射线医学、X射线和伽玛非破坏测试、射线照相、海关X光装置、辐射紧急事件、辐射监视、核能工业、加速度装置、科学研究等
详情介绍:
AT1121A

简介
·特点
·便携式、多功能、宽量程
·短时辐射和脉冲辐射(AT1123、AT1123A)
·塑料闪烁体(重金属混合物)检测体
·γ、β辐射源搜索
·暴露时间评估
·内置LED稳定系统,无需使用参考源
·大屏幕背光LCD
·远程测量
·超过限值时声音和可视报警
·三种供电模式
·极端环境下操作

应用领域
·X射线诊断放射医学
·辐射检测应急事件
·核工业原子能研究
·X γ非破坏性测试
·INSTRUMENTS AND

比较
 
AT1121
AT1121A
AT1123
AT1123A
辐射
H*(10)
H*(10)
H*(10)
H*(10)
X射线
+
+
+
+
γ辐线
+
+
+
+
轫致辐射
+
+
+
+
连续
+
+
+
+
短时
+
+
+
+
脉冲
-
-
+
+
β探测
+
+
+
+

技术参数
检测体 塑料闪烁体(重金属混合物),30×15 mm
环境剂量当量 50 nSv - 10 Sv
连续辐射的环境剂量率当量
AT1121 AT1123 50 nSv/h - 10 Sv/h
AT1121A AT1123A 50 nSv/h - 5 Sv/h
短时辐射的环境剂量率当量
AT1121 AT1123 50 nSv/h - 10 Sv/h
AT1121A AT1123A 50 nSv/h - 5 Sv/h
脉冲辐射的环境剂量率当量
AT1121 AT1123 1 μv/h - 10 Sv/h
AT1121A AT1123A 1 μSv/h - 5 Sv/h
*小脉冲时间(剂量率达到1.3 Sv/s) 10ns
*小脉冲时间(短时辐射) 30ms
能量范围
AT1121 AT1123 0.015 –10MeV
AT1121A AT1123A 0.02 –10MeV
137Cs能量响应灵敏度
from 15 keV to 60 keV ±35%
from 60 keV to 3 MeV ±25%
from 3 MeV to 10 MeV ±50%
137Cs灵敏度 100 cps/μSv h-1
伴随性β辐射灵敏度 3 ·10-7 μSv ·h-1·Bq-1
操作模式设置时间 1 min
连续操作时间
交流电或直流电 不少于24h
内置蓄电池 不少于12h
操作温度范围
AT1121 AT1123 -30 - +40℃
AT1121A AT1123A -30 - +50℃
剂量和剂量率测量误差 ±15%
校准误差 ±5%
操作温度范围内补偿误差 ±10%
相对湿度(+ 35°C) 98 %
防护等级 IP54
电源要求
内置蓄电池 6V
交流电 220V
直流电 12V
放射干扰标准 CEI/IEC CISPR 22:1997
EMC兼容性 CEI/IEC 61000-4-2:1995
IEC 61000-4-3:1995
重量 0.9 kg
尺寸 233×85×67 mm

标准配置
·辐射检测仪
·“0.06 - 10 MeV”帽(带过滤器)
·皮带、AC适配器、手柄、皮套、操作指南

可选件
·25m远程控制线、视听报警单元(连接线达到25m长时)
·计算机连接线和应用软件、直流电连接线
·1.6m伸缩杆、包装箱
本检测仪的主要功能是检测脉冲时间从10ns起的脉冲辐射
·脉冲持续时间从30ms起的短时辐射以及宽范围能量和环境剂量率当量的连续X射线和γ辐射
·本检测仪可探测各种软的和硬的γ辐射源,β辐射源
·带有暴露时间评估的脉冲辐射和短时辐射以及探测移动的辐照装置
·使用仪器上的键盘可设置量程范围内的任何限值
·仪器自动保存*大剂量率值
·内存中可长时间保存100个测量结果并能以300到19200波特的速率将数据传输给计算机
·本检测仪在接通启动时和整个操作过程中都可有自检模式,并且因为LED的稳定性测量方法而不需要任何参考源

 
 
 
X-RAY AND GAMMA RADIATION DOSIMETERS AT1121, AT1121A AND AT1123

 Handheld wide-range multifunctional instruments for continuous, short-term and pulsed x-ray and gamma radiation dosimetry
 
Features

  AT1121,
AT1121A
AT1123
Radiation DR D DR D
X-ray + + + +
Gamma + + + +
Bremsstrahlung + + + +
Continuous + + + +
Short-term + + + +
Pulsed - - + +
Beta (detection) + + + +


- Handheld multifunctional wide-range instruments  
- Tissue-equivalent detector - scintillation plastic with heavy metal admixtures  
- Gamma and beta radiation source search  
- Short-term radiation from 30 ms (AT1121, AT1121A) and pulsed radiation from 10 ns (AT1123)  
- Exposure time assessment  
- Built-in LED stabilization system of the measuring path providing no need to use a reference source  
- Large backlit LCD  
- Remote measuring with remote control  
- Audible and visual alarm at threshold exceeding  
- Logging up and transferring measurement results to PC  
- Three types of power  
- Extreme environment operation  


Application

- X-ray diagnostics
- Nuclear medicine
- Radiology
- X-ray and NDT
- Radiography
- Customs x-ray equipment
- Radiation emergency
- Radiation monitoring
- Nuclear industry
- Acceleration equipment
- Scientific research


The main dosimeter function is to measure pulsed radiation with a pulse duration from 10 ns (AT1123), short-term radiation with a pulse duration from 30 ms and continuous x-ray and gamma radiation in wide ranges of ambient dose equivalent rate and energy. The instruments detect soft and hard gamma radiation sources, beta radiation sources, short-term and pulsed radiation with exposure time assessment, and detect moving irradiators as well. Use the instrument keyboard to setup any thresholds from the whole measuring range. The instruments save automatically the maximum dose rate value. They keep for long time 100 measurements results in the nonvolatile memory and they are able to transfer data to PC with the rate from 300 to 19200 baud.
The instruments have the self-testing mode which starts at switching-on and continues within dosimeter operation. There is no need to use a reference source because of LED stabilization of the measuring path.

Specification
 
Detector scintillation plastic with heavy metal admixtures,
ø  30 х 15 mm
Ambient dose equivalent rate measuring range  
AT1121, AT1123 50 nSv/h - 10 Sv/h
AT1121A 50 nSv/h - 5 Sv/h
Ambient dose equivalent rate measuring range of short-term radiation  
AT1121, AT1123 50 nSv/h - 10 Sv/h
AT1121A 50 nSv/h - 5 Sv/h
Ambient dose equivalent rate measuring range of pulsed radiation  
AT1123 1 µSv/h - 10 Sv/h
Minimum pulse duration at dose rate up to 1.3 Sv/s within the pulse 10 ns
Minimum pulse duration for short-term radiation 30 ms
Ambient dose equivalent measuring range 50 nSv - 10 Sv
Energy range  
AT1121, AT1123 0.015 - 10 MeV
AT1121A 0.02 - 10 MeV
Energy sensitivity response
respect to 137Сs
 
from 15 keV to 60 keV ± 35 %
from 60 keV to 3 MeV ± 25 %
from 3 MeV to 10 MeV ± 50 %
Sensitivity to accompanying beta radiation of 90Sr + 90Y at 5 cm when the cap '0.06-10 MeV' is on 3·10-7 µSv·h-1·Bq-1
Sensitivity on 137Сs 70 cps/µSv·h-1
Operation mode setup time 1 min
Continuous operation time  
AC mains or DC supply not less than 24 h
built-in accumulator unit not less than 12 h
Operating temperature range  
AT1121, AT1123 - 30 - + 40°С
AT1121A - 30 - + 50°С
Intrinsic measurement error ± 15 %
Calibration error ± 5 %
Complementary error within operating temperature range ± 10 %
Relative humidity at +35°С 95 %
Protection class IP54
Power requirements  
built-in Ni-MH accumulator unit 6 V
AC mains, 50 Hz 220 V
DC supply 12 V
Radio disturbance  
CEI/IEC CISPR 22:1997  
Electromagnetic compatibility  
CEI/IEC 61000-4-2:1995  
IEC 61000-4-3:1995  
Weight 0.9 kg
Dimensions 233х85х67 mm



Complete set: dosimeter, cap '0.06-10 MeV' with filter, AC adapter, hand strap, handle, holster and Manual.

Remote control with the cable up to 25 m long, audible and visual alarm unit with the cable up to 25 m long, cable to connect PC and applied software, cable for DC supply, telescopic bar 1.6 m, packing case are options and they are supplied on additional order.

X-ray and gamma radiation dosimeters AT1121, AT1121A and AT1123 have pattern approval certificates of Republic of Belarus, Russian Federation, Ukraine, Lithuania and Kazakhstan.

They comply with IEC 60846 International standard requirements.

标题:
内容:
联系人:
联系电话:
Email:
公司名称:
联系地址:
 
 
注:1.可以使用快捷键Alt+S或Ctrl+Enter发送信息!
2.如有必要,请您留下您的详细联系方式!

粤公网安备 44049102496292号