- CPTG
- GOSSEN
- 瑞士富巴(HUBA)
- 美国HTM接近开关、电感传感器...
- 美国美亚过程控制公司Meria...
- 物液位测量与控制
- 流量测量产品
- 过程称重与控制
- 电量测量与控制
- 液体分析与控制
- 气体分析与测量
- 压力测量与控制
- 温度测量与控制
- 阀门及气电转换产品
- 便携式检测仪器
- 系统与集成
- 美国诺南RONAN公司测控产品
- 美国ELECTROSWITCH...
- 美国PRECISION系列数字...
- 瑞士Rotronic温湿度产品...
- 阿通特斯 ATOMTEX 核辐...
- 德国GMC、瑞士CAMILLE...
- 英国盖姆(GEMS)/德国菲尼...
- 其它代理品牌
- MTR膜分离技术及logsto...
LS-30静压水库泄漏传感器
Hydrostatic Resev. Sensor [LS-30]
Ronan Engineering抯 Model LS-30 Hydrostatic Reservoir Leak Sensor is designed to detect changes in liquid level within reservoirs of hydrostatic monitored double-wall tanks. Constructed of 304 stainless steel, polysulfone, Beryllium Copper and PVC, the LS-30 will provide years of trouble free service.
Typical Applications
- Double Wall Fiberglass Tank Reservoir Monitoring
- Low and Low Low Level Monitoring
- High Level/Overfill Monitoring
- Vertical Application Dual Point Level Sensing
The LS-30 can be installed to provide discrete indications of liquid increase or liquid loss, or provide high or low liquid indications. A breach of the tanks inner wall will allow reservoir liquid to escape the interstice into the primary tank, and a reservoir level drop will occur. A breach of the outer tank wall will allow reservoir liquid to escape the interstice into the environment, or ground water to enter the interstice, and a reservoir level change will occur. Liquid increase or loss, sufficient to move the sensor抯 float will transmit a signal to the control panel to initiate control functions or annunciate alarms.
Ronan抯 LS-30 Sensor operates on a direct principle. Glass encapsulated, hermetically sealed, reed switches are embedded within the sensor stem. Permanent magnets within the sensor floats create a magnetic field which surrounds the reed switches. When a magnetic field is removed by movement of one or both floats, the reed switch is actuated, thereby changing state. This condition either opens a closed switch or closes an open switch. This change in state is then signaled to the control panel.
The LS-30抯 design allows rigid or flexible mounting for easy periodic testing as required by many regulatory agencies. The sensor may be mounted loosely suspended by its cable, or rigid with the 1/2 inch NPT nipple. The LS-30 may also be supplied with the optional RC-4 four inch riser cap assembly. The LS-30 is supplied with the low circuit N.O. and the high circuit N.C. Other logic configurations are available by specifying at time of order.
Specifications
- Wetted Parts: 304 and 316 Stainless Steel, Beryllium Copper, Polysulforne, PVC
- Mounting: 1/2" NPT, male
- Switch Rating: SPST, 20VA, 120-240 Vac pilot duty
- Operating Temperature: -40篎 to +225篎 Temperature:
- Float S.G.: 0.65
- Pressure: 75 psi maximum
- Cable: PVC jacket, 2 twisted pair, 20AWG, 15 ft
Related Support Material : Hydrostatic Resev. Sensor Key: [L] = Registration Required - [R] = Reps Only | |||||||||||||||||||||||||||||
|