- CPTG
-
GOSSEN
-
瑞士富巴(HUBA)
- 美国HTM接近开关、电感...
-
美国美亚过程控制公司Me...
-
952 系列法兰型孔板流...
-
951 偏心孔板流量计(...
-
72H系列高压湿塔Acc...
-
70H系列高压湿塔Acc...
-
43H系列插入式带一体式...
-
40H系列插入式带一体式...
-
37L系列高压湿塔Acc...
-
33T系列低压型Accu...
-
25D系列法兰安装型Ac...
-
24D 系列法兰安装型A...
-
23L系列高压型,插入式...
-
22L系列高压型,插入式...
-
21T系列低压型,插入式...
-
20T系列低压型,插入式...
-
11A系列内嵌型Accu...
-
10A系列内嵌型Accu...
-
Meriam孔板流量解决...
-
ACCUTUBE流量解决...
-
MP-100KT 校准泵
-
1020 差压单元
-
952 系列法兰型孔板流...
- 物液位测量与控制
- 流量测量产品
- 过程称重与控制
-
电量测量与控制
-
COMBINE M201...
-
COMBINELINE系...
-
COMBINE 3580...
-
COMBINE 3500...
-
MZC-203回路阻抗测...
-
MRP-120系列RCD...
-
MMR-620欧姆表
-
MRU-200接地电阻和...
-
CMP2钳形表
-
TKF-13相序和电机旋...
-
TKF-12C相序测试仪
-
MIC系列绝缘电阻测试仪
-
MIE 5000电气安装...
-
MPI 5200多功能电...
-
MPI 5250多功能电...
-
COMBINE 1414...
-
COMBINE 1007...
-
COMBINE 1005...
-
COMBINE 1312...
-
COMBINE 31XX...
-
COMBINE M201...
-
液体分析与控制
-
浊度测量控制仪
-
PH和电余氯测量控制仪
- 电导率测量控制仪
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
MicroPRESS M...
-
浊度测量控制仪
-
气体分析与测量
- 过程校准器
- 室内空气质量分析仪
- 暖通燃烧分析仪
- 手持式工业排放分析仪
- 美国新星气体分析系统
- 德国汉斯(Hans He...
- 美国塞弗(safetys...
-
日本RIKEN 系列气体...
- RM-570/580 系...
- GP-641 系列控制器
- GP-146 指示报警单...
- RM-590 系列控制器
- GD-K71D型智能型半...
- GD-F77D-NT 氧...
- GD-F77D氧气(O2...
- GD-V77D-NT 可...
- GD-V77D可燃气体探...
- GD-S77DG-NT ...
- GD-S77DG有毒气体...
- GD-K77DG-NT有...
- GD-K77DG有毒气体...
- GD-K71D-NT 毒...
- GD-K71D毒性气体探...
- GD-K7DII 吸入式...
- GD-D5C 吸入式可燃...
- GD-D8 吸入式可燃气...
- RI-215系列 红外线...
- GD-F44 扩散式氧气...
-
丙烯酸丁酯探测器
-
异丙醇气体探测器
-
磷化氢气体探测器
-
氢氰酸气体探测器
-
硫化氢气体探测器
-
正己烷气体探测器
-
硅甲烷气体探测器
-
氯化氢气体探测器
-
环氧乙烷探测器
-
乙酸乙酯探测器
-
六氟化硫探测器
-
四氟化碳探测器
- 压力测量与控制
-
温度测量与控制
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
COMBINE HT88...
-
阀门及气电转换产品
-
TOKO东控阀门(原装进...
- V-6850系列陶瓷碟型...
- V-6500C系列高压小...
- V-6420系列浮筒式单...
- T-8710系列钽材波纹...
- T-8660系列Y型先导...
- T-8320系列小型三通...
- T-8050系列小型全塑...
- T-5705系列高压波纹...
- T-5675系列衬胶可分...
- T-8960系列直通波纹...
- T-8950系列角形波纹...
- T-8940系列隔膜角型...
- T-8930系列一体三通...
- T-8910系列分体角型...
- T-8900系列分体直通...
- R-2000系列衬胶滚筒...
- V-5514系列金属密封...
- V-5513系列PTFE...
- V-5512系列橡胶密封...
- V-5510系列双偏心蝶...
- AKO系列管夹阀
-
美国COMBINE执行机...
- YT-405型保位阀
- YT-300型气动放大器
- AS3000-02型速度...
- SR/AW30型过滤减压...
- ITS300型角行程防爆...
- ITS100型角行程限位...
- 1Lx7001型直行程防...
- WLGCA2型直行程限位...
- M15G-8型两位五通电...
- M00U-8型两位三通电...
- 3760型小型内藏式阀门...
- YVP-110型数字式阀...
- IP-8001型HART...
- TP-601型气/气阀门...
- TP-351型电/气阀门...
- CMC-103电动式执行...
- CMS-020/040电...
- PSN系列高性能电子式伺...
- MSP系列小型电子式执行...
- C-25系列汽缸式执行机...
- 美国COMBINE电气转...
-
德国西门子SIEMENS...
- 771系列电气转换器Cu...
- 77 系列电气转换器Cu...
- 73N-B1内置式阀门定...
- 73N-B内置式阀门定位...
- 73N-FR内置式阀门定...
- 73N24F内置式阀门定...
- 73N12F内置式阀门定...
- 74-SN1阀门定位器 ...
- 74-SG1阀门定位器 ...
- 760P6阀门定位器 V...
- 760P5阀门定位器 V...
- 760P4阀门定位器 V...
- 760P2阀门定位器 V...
- 760P1阀门定位器 V...
- 760E1阀门定位器 V...
- 2306系列仪表空气过滤...
- 91-HF系列过滤减压阀...
- 661带偏压 的放大继电...
- 66 放大和减小继电器A...
- 63SDL常数差流量控制...
- 芬兰Larox 阀门(管...
-
TOKO东控阀门(原装进...
- 便携式检测仪器
- 系统与集成
- 美国诺南RONAN公司测...
- 美国ELECTROSWI...
- 美国PRECISION系...
- 瑞士Rotronic温湿...
X500F系列事件记录仪
Sequence of Events Recorders [X500F]
![]() |
The new Ronan X500F Sequence of Events Recorder provides the Power Generation, Power Distribution, and Process Industries with the most advanced monitoring and fault finding data acquisition system. The systems high speed, high resolution digital multiplexers utilize network interface for open and fast transmission of plant status changes to the operator on local HMI or a remote host and visual annunciators.
The multiplexers simultaneously store the historical event information internally, as well as a duplicate storage in the local or remote Ronan HMI software X1000 for equipment failure and shutdown analysis. The new Ronan digital multiplexer provides a user friendly network browser interface for input/output configuration, on-line alarm view, and local multiplexer history browsing.
The new Ronan Windows operating system based X1000 application software presents clear and simple event information, operator interaction, and status of all inputs via multiple split window on a single video screen display. The ability to group plant or equipment related inputs allows immediate access to the specific event information or routing to different displays/peripherals.

A complete system configuration consists of field contact termination facilities, network multiplexers, network hub(s), X500F HMI industrial computers and peripherals such as keyboards and mouse, color video, printers, and the optional window type annunciators. For critical applications the dual function SER/Visual Annunciator Systems are supplied in fully redundant configuration, where the loss of a single train does not adversely affect the information flow to the operators.
FEATURES
Multiplexers
- 128 Channel Multiplexers with Ethernet Output, GPS Time Receiver and IRIG-B Time Code Generator 200 μsec Time Resolution
- 1 msec Resolution
- Browser Interface to Multiplexer for Configuration, Event Display and History View
- Local 8,000 Event Storage
- Selectable Network Communication Protocol:
- Ronan Proprietary
- IEC60870 Over TCP/IP
- DNP 3.0 Over TCP/IP
- Single Train or Multiple Redundant Architecture
- Continuous Multiplexer Hardware/ Software Diagnostics
- Live, Logic, or Dry Contact Input (Opto-isolated)
- Input Filter - Digital, 1 to 64,000 ms Δt for Alarms, Return-to-normal and Debounce, Selectable for Each Input
- Automatic Disable/Enable of Inputs by Programmable Limit Mode
- Enable/Disable of Individual Inputs
- Periodic Front End Input Test (Automatic)
- Access Protection through Web Browser by Multi-level Programmable Passwords
Ronan HMI Software
- Grouping of Events for Video Display or Printout
- Multiple Split Window Display of Events, Operator Interaction, System Diagnostic Status, and Input State
- 500,000 Event History Storage
- NTP (Network Time Protocol) for Time Synchronization with 100 msec Resolution
- Search/Review of Event History Database
- Selective Data Printout and Screen Print
- Boolean Function Processing, Alarm Sequence Processing, and Simulator Processing
- Network Time Synchronization
- Configurable Window Annunciator and Mimic Display Views
- Comprehensive Configuration Management Agent
- Multiplexer Distributed or Client/ Server Systems Architecture
- Open Protocols for External Host Interface
Ronan HMI Computer Hardware
- Industrial Grade, Seismic/Environ- mental Qualified, Rotating or Solid State Disk Memory, Pentium Class Microprocessor
- Single or Dual Network Interface
- Internal or Dual External Power Supplies
- Co-processor for Boolean Function Processing and Alarm Sequence Engine
- Active Relay Output for Hardware and Software Supervisory Monitoring

NETWORK HUBS
8 or 16 channel network hubs standard or switched with redundant power supply. RJ45 connector with one uplink feed.
BUILDINGS BLOCKS
Termination Facilities
The Ronan Field Termination Facilities (FTA) provide Elco 8016 connectors; four for dry contacts, and eight for live contacts. Cable assemblies, equipped with one Elco connector for connection to the multiplexer and pigtail end for connection to the customer’s existing field contact termination facilities are most commonly supplied. Ronan may supply one of a number of standard field termination facilities, or custom designed type to accommodate for special requirements. The field termination assembly typically provides for screw or compression, single or multiple output connection for interface to the multiplexers, and to digital control system (DCS), programmable logic controller (PLC), or plant computer. Additional features in standard designs are field contact isolation switches, sliding link terminals, field contact status indicators, diode gating or opto-isolators for multiple output requirements, and ground fault detection.

Multiplexers
The X501NET Multiplexers, designed for industrial application, are available for rackmount or surface mount NEMA (IP) enclosures. Each multiplexer houses single or dual power supplies for field contact and logic voltage capable of accepting single or dual power sources such as 115/235 Vac or 115 Vac/125 Vdc or 24, 48 Vdc. The single or dual multiplexer-controller provides for input card status interrogation, time tagging of events to 1 ms resolution, storing of up to 8,000 events, queuing of events, and transfer of events via several popular configurable communication protocols (IEC 60870, DNP 3.0, TCP/IP) over 10 Mbs 10baseT communication layer to the respective subscribers of events present on the network. Additional standard features are built in GPS time receiver with simple cable/antenna interface and IRIG-B generator output, temperature controlled precision oscillator, NTP (Network Time Protocol) for backup synchronization and complete web server for simple browser interface configuration and monitoring facilities. Up to 8,000 local event data storage, hardware/software diagnostic, field contact input test with an option that includes the opto-isolator input circuit. The sixteen input modules, each serving eight input contacts, are microprocessor controlled for input status interrogation, status change queuing, digital filters by individual inputs for alarm, return-to-normal, debounce, and normally open/normally closed field contact logic. This multiplexer is a self-sustained event acquisition, recorder, and producer unit.
Network Hubs 
The network hubs, available in sixteen channel rackmount or eight channel surface mount, are utilized to place network devices such as multiplexers, HMI computers and Ronan X110NET Serial Annunciator on to a common network segment while providing complete physical isolation and switched port design chatter suppression for a much higher network integrity system. The chassis design features rugged industrial packaging with single or dual power source such as 115/230 Vac, 50/60 Hz, or 24, 48, or 125 Vdc.
HMI HARDWARE/SOFTWARE
Ronan Industrial Computer
The X500F Industrial Grade Computer is available in table top or rack mount design, tested for high level of Seismic application as well as RFI/EMI susceptibility requirements. Internal power supply for single source application, solid state memory, the CPU module, based on a Pentium class processor (upgradeable to higher performance CPUs). The computer is also available with external power supply for dual power source input, such as 115/230 Vac, 50/60 Hz or 24, 48, and 125 Vdc. A compact 1U configuration (1-3/4” high) computer is also offered for less critical applications. A complete HMI computer is offered with rack mount or table top housing, color L.C.D. for video display of available sizes, Color Dot Matrix printer for alarm/report printout, and color laser printer for custom color report printing. The printers are offered as dedicated serial printers or network printers depending on the system’s architecture.
X500F SOFTWARE (X1000)
HMI (Human Machine Interface)
The Ronan X500F Sequence of Events Recorder is provided with several different versions of highly integrated, Windows based operator interface software uniquely designed to suit different applications and system complexities.
X1000 Integrated
This Windows based application is generally used with small and large systems where all equipment is connected to a single network segment and applications requiring local database of sequence of events as well as redundant data acquisition needs. The main software task is to provide, in clear and concise format of the event data, event storage, operator action, system’s health, and current state of the field contacts. Software access is comprehensively password protected for different levels of users with different access rights and privileges. The system is ideally suited for remote sub-stations, switchyards, power and process monitoring. The software provides configuration database for selection of normally open/normally closed field contact logic, filter parameters, display parameters, alarm sequences, network connection and user rights and group assignment. All event data is stored in the rigid disc or solid state memory. The historical information of up to 500,000 events may be reviewed on the screen in its entirety or queried with specific parameters for an accurately sorted display of information or hard copy. The new flexible Windows user interface event information is displayed in an event windows format which is user configurable. System messages use a second window. The system’s time is continuously synchronized via NTP client receiving time data from an NTP server.
X1000 Server/Database/Client
This group of software is specifically designed to provide a client/server architecture through the use of system network. The software consists of clients user interface application and producer server/database for central-remote data acquisition application. A typical application of the software is to continuously gather accurate 1 msec resolution event data from many remote locations into a central data repository location via dedicated Ethernet network structure or public Internet connection (Broadband). The software package X1000 consists of one or more client user interface software which is similar to the Ronan standard integrated software. Producer software is provided as one of the components of the central server software that accompanies a third-party licensed database software. The central station is provided with a GPS synchronized network time server that communicates to all network time clients inside each multiplexer and X1000 software via NTP protocol, providing an accurate system time synchronization.
REPORTS
The X500F system provides hard copy printout of all recorded data at the operator’s request. Reports such as Current Alarms, Event History, Message History and Legends are generated and printed as needed. The application query feature allows sorting of stored data by any one record, or a combination of records in logical order. The system then allows easy print out of queried data as seen on the screen to a report printer on the network. The application uses all of the advanced features of the Windows operating system print functionality for printing.
PERIPHERALS
Videos — A wide variety of color LCD or CRT monitors is available for use with X500F HMI systems. Various resolutions and sizes are available for table top, panel or rack mounting.
Printers — Various color or black and white serial or network printers are available for report or alarm printing. Industrial grade impact printers are also available with 80 or132 characters wide for continuous alarm printing.
Serial Input Visual Annunciators — The X500F system has the ability to send serial events via the network to X110 NET Ronan serial network annunciator for visual annunciation on all Models of the Ronan lamp cabinets.
Host Connectivity — The Ronan network multiplexers provide host connectivity via IEC 60810, DNP3 and Ronan proprietary protocol to host device.
Plant Process Monitoring
The X500F basic system configuration consists of field contact termination facilities, network multiplexers, network hub, HMI computer unit including the support modules based on system requirement, a color monitor, and one or more serial or networkable printers. The field termination facilities are connected to the multiplexers via multiple conductor cable assemblies. The network cat5 10baseT cable is connected to a central hub which is connected via similar cable to the computer’s network module hosting the Ronan HMI software. The system may, optionally, provide input status information to the Ronan network X110 NET serial input visual annunciator.

Dual Train Redundant System
For critical applications such as nuclear or conventional power plants, petro, petro chemical or chemical processes, the system may be configured in dual redundant trains. To achieve highest reliability and MTBF requirements for this type of requirements, all equipment is duplicated to provide two complete trains, connected via two networks, to the HMI computers which provide output to the color video and printer(s). Optionally, the system may provide input status changes to a redundant network serial input visual annunciator. All host interfaces are connected via the network hub.

Remote Monitoring/Event Recording With Central Data Acquisition - Management
Multiple site SER systems typically utilized in power distribution and switchyard applications require transfer of event information and site input configuration to and from a central master station. These remote SER systems are connected to the master station via dedicated Ethernet network or Broadband network. Ronan utilizes a client/server architecture using several different TCP/IP based protocols such as IEC-60870, Ronan proprietary protocol to communicate between remote sites and central station. Clients reside in each multiplexer with its own dedicated IP address and connect to the central server/producer. All remote input configuration can be set up from the master station server application. Optionally, a local HMI display and data recorder is available at each remote SER site with its own display and CRT for local monitoring and maintenance. Real time synchronization between multiple remote sites and central site for area wide synchronization is achieved by GPS (Global Positioning System) signal feed to each multiplexer and at central site through a GPS receiver/network time server.

| Related Support Material : Sequence of Events Recorders Key: [L] = Registration Required - [R] = Reps Only | |||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||







